Clinical usefulness of MLCs in robotic radiosurgery systems for prostate SBRT

نویسندگان

  • Masashi Tomida
  • Takeshi Kamomae
  • Junji Suzuki
  • Yoichi Ohashi
  • Yoshiyuki Itoh
  • Hiroshi Oguchi
  • Takahito Okuda
چکیده

Stereotactic body radiation therapy (SBRT) using recently introduced multileaf collimators (MLC) is preferred over circular collimators in the treatment of localized prostate cancer. The objective of this study was to assess the clinical usefulness of MLCs in prostate SBRT by comparing the effectiveness of treatment plans using fixed collimators, variable collimators, and MLCs and by ensuring delivery quality assurance (DQA) for each. For each patient who underwent conventional radiation therapy for localized prostate cancer, mock SBRT plans were created using a fixed collimator, a variable collimator, and an MLC. The total MUs, treatment times, and dose-volume histograms of the planning target volumes and organs at risk for each treatment plan were compared. For DQA, a phantom with a radiochromic film or an ionization chamber was irradiated in each plan. We performed gamma-index analysis to evaluate the consistency between the measured and calculated doses. The MLC-based plans had an ~27% lower average total MU than the plans involving other collimators. Moreover, the average estimated treatment time for the MLC plan was 31% and 20% shorter than that for the fixed and variable collimator plans respectively. The gamma-index passing rate in the DQA using film measurements was slightly lower for the MLC than for the other collimators. The DQA results acquired using the ionization chamber showed that the discrepancies between the measured and calculated doses were within 3% in all cases. The results reinforce the usefulness of MLCs in robotic radiosurgery for prostrate SBRT treatment planning; most notably, the total MU and treatment time were both reduced compared to the cases using other types of collimators. Moreover, although the DQA results based on film dosimetry yielded a slightly lower gamma-index passing rate for the MLC than for the other collimators, the MLC accuracy was determined to be sufficient for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of prostate cancer local recurrence after whole-gland cryosurgery with frameless robotic stereotactic body radiotherapy: initial experience.

BACKGROUND The use of frameless robotic stereotactic body radiotherapy has not been investigated in patients whose primary cryosurgery treatment failed. The aim of this series was to present initial experiences with frameless robotic radiosurgery in the treatment of local prostate recurrence after cryotherapy. METHODS We reviewed the outcome of frameless robotic radiosurgery in 4 patients for...

متن کامل

A single-center study of 100 consecutive patients with localized prostate cancer treated with stereotactic body radiotherapy

BACKGROUND Radiotherapy is an increasingly preferred treatment option for localized prostate cancer, and stereotactic body radiation therapy (SBRT) a relatively established modality of therapeutic irradiation. The present study analyzes the toxicity and biochemical efficacy of SBRT in 100 consecutive prostate cancer patients treated with CyberKnife Robotic Radiosurgery System. METHODS One hun...

متن کامل

CyberKnife radiosurgery for prostate cancer.

Treatment of prostate cancer with SBRT is an area of significant controversy for many in the radiation oncology community despite radiobiologic data that strongly suggest the prostate would be an excellent SBRT target. Recently, new data have emerged that show promising outcomes with minimal toxicity for CyberKnife SBRT of prostate cancer. In the following we present the motivating factors for ...

متن کامل

Editorial: Clinical Application of Stereotactic Body Radiotherapy (SBRT): Cranium to Prostate

Stereotactic radiosurgery is a relatively recent radiation technique initially developed using a framebased system in 1949 by a Swedish neurosurgeon, Lars Leksell, for lesions not amendable to surgical resection. Radiosurgery is founded on principles of extreme radiation dose escalation, afforded by precise dose delivery with millimeter to submillimeter accuracy. Building upon the success of fr...

متن کامل

Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

BACKGROUND Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. METHODS A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent rob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017