Comparison between hydrogen clearance and microsphere technique for rCBF measurement.
نویسندگان
چکیده
Regional cerebral blood flow was measured repeatedly in anesthetized and immobilized cats under various experimental conditions by recording the clearance of inhaled hydrogen with inserted platinum electrodes and by recording the distribution of 15 mu microspheres labeled with 3 different radioisotopes. The values for both methods in normal cortical tissue were comparable (75.7 +/- 23.5 ml/100 g min for H2-clearance; 67.6 +/- 26.2 ml/100 g min for microsphere technique), but were below those recorded in awake cats. With both methods the values could be reliably reproduced (correlation coefficient between measurements: 0.903 for H2-clearance, 0.754 for microsphere technique). During ischemia induced by temporary occlusion of the middle cerebral artery the microsphere technique usually yielded higher flow values than the H2-clearance, and did not indicate severe ischemia in 6 out of 20 instances. After restoration of flow, hyperperfusion was observed by the microsphere technique in 2 cases only while H2-clearance indicated hyperemia in 6 instances. This limited comparability between the 2 methods was also expressed in a low correlation coefficient (0.486) calculated from 139 flow values obtained simultaneously with both methods. The discrepancy between the methods under pathological conditions might be due mainly to the different recording volumes: while Pt-electrodes record H2-clearance from a few mm3 or less, tissue samples of 300-700 mg were necessary for the microsphere technique and inhomogeneities of flow may thereby escape detection. The technique for measuring cerebral blood flow in an experimental setup should be selected according to the requirements of the study and according to the limitations of the various methods.
منابع مشابه
Regional cerebral blood flow determination by the hydrogen clearance technique and comparison with oxygen availability in the rabbit.
Regional Cerebral Blood Flow Determination by the Hydrogen Clearance Technique and Comparison With Oxygen A variability in the Rabbit • Hydrogen clearance using the tissue polarographical electrode appears to be a potentially useful technique for intermittent measurements of rCBF in relatively small areas. Both chronic and acutely implanted electrodes were placed at different depths in rabbit c...
متن کاملValidation of CBF measurement with non-invasive microsphere method (NIMS) compared with autoradiography method (ARG).
The purpose of this study is to examine the correlation of measured regional cerebral blood flow (rCBF) by means of a new microsphere method (non-invasive microsphere method), to the autoradiography (ARG) method, which is an established quantification method for 123I-IMP brain SPECT. The non-invasive microsphere (NIMS) method and ARG method were simultaneously applied to 30 patients, and quanti...
متن کاملA simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method
Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...
متن کاملComparison of thermal clearance measurement of regional cerebral blood flow with radiolabelled microspheres.
A thermal clearance technique for measuring cerebral blood flow is described and compared with the radiolabelled microsphere technique. The thermal technique involves measurement of the rewarming curve generated after bolus infusion of 4-5 ml of ice-cold saline into the common carotid artery with a subdural thermistor placed on the parietal cortex. Evaluation of the biexponential decay curves o...
متن کاملDynamic CT measurement of cerebral blood flow: a validation study.
BACKGROUND AND PURPOSE Our objective was to develop a method to correct for the effect of partial volume averaging (PVA) in the CT measurement of contrast enhancement in small arteries, and to validate a dynamic contrast-enhanced CT method for the measurement of regional cerebral blood flow (rCBF). METHODS Contrast-enhanced CT scans of tubes of known inner diameters were obtained to estimate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 12 2 شماره
صفحات -
تاریخ انتشار 1981