A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy

نویسندگان

  • Rodolfo Luis Vigo
  • Tomás Ortiz-Basso
  • María Natalia Vilas
  • Jorge Prémoli
چکیده

PURPOSE To describe the use of a ruler to increase the accuracy and customization of Lester Jones tube placement. MATERIALS AND METHODS This was a review of 92 patients who underwent minimally invasive conjunctivodacryocystorhinostomy using this instrument. RESULTS The success rate was 100%, with an average operating time of 15 minutes. In nine patients, late migration of the Jones tube into the nasal cavity required a secondary intervention, with successful Jones tube repositioning. In five cases, obstruction of the tube opening was caused by conjunctival overgrowth. CONCLUSION The millimetric ruler engraved in the sleeve of the trocar allows measuring and placing a personalized tube for each patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frosted jones pyrex tubes.

PURPOSE To describe the use of a new, frosted Jones Pyrex tube in the treatment of obstructed canaliculi of the upper lacrimal system. The frosted Jones tube retains the advantages of the traditional smooth Pyrex tube yet appears to improve the positional stability in the surgically created fistula. METHODS Ten patients of a single surgeon who had previously undergone external conjunctivodacr...

متن کامل

Modified conjunctivodacryocystorhinostomy for upper lacrimal system obstruction.

OBJECTIVE To describe a modified technique for conjunctivodacryocystorhinostomy (CDCR) and to compare this technique with the standard transcaruncular placement of the glass tube. METHODS Patients with upper lacrimal system obstruction underwent CDCR at the Jules Stein Eye Institute during a 3-year period. Thirteen patients underwent modified CDCR leaving the caruncle intact, while 7 patients...

متن کامل

Minimally invasive conjunctivodacryocystorhinostomy with Jones tube.

PURPOSE To describe a minimally invasive technique for conjunctivodacryocystorhinostomy with the Jones tube. This technique creates a direct communication between the conjunctiva and the middle meatus with the use of a 14-gauge angiocatheter. The glass tube is inserted under endoscopic or direct visualization. METHODS A retrospective review of consecutive patients who underwent the minimally ...

متن کامل

Comparison of Medpor Coated Tear Drainage Tube versus Silicon Tear Drainage Tube in Conjunctivodacryocystorhinostomy: Problems and Solutions

PURPOSE This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. METHODS Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coate...

متن کامل

Case Report of Sump Syndrome after Laser Conjunctivodacryocystorhinostomy

The sump syndrome was initially described in relation to patients who had undergone external dacryocystorhinostomy. Here we report a case of sump syndrome that developed following laser conjunctivodacryocystorhinostomy (CDCR) due to tube displacement after a bout of forceful sneezing. Unlike cases of external dacryocystorhinostomy where flaps are sutured, there is a potential space created by t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015