A comparison of upper-limb motion pattern recognition using EMG signals during dynamic and isometric muscle contractions

نویسندگان

  • An-Chih Tsai
  • Tsung-Han Hsieh
  • Jer-Junn Luh
  • Ta-Te Lin
چکیده

Multichannel electromyography (EMG) signals are one of the common methods used in human motion pattern recognition. In exoskeleton robot control, EMG signals are measured during dynamic or isometric muscle contractions. Various types of contraction can cause EMG signals to vary, affecting recognition performance. A motion pattern recognition model using EMG signals from either dynamic or isometric muscle contractions has not yet been fully investigated. In this study, a novel feature extraction method, using the short-time Fourier transform ranking (STFT-ranking) feature, was employed to determine multichannel EMG signals. The performance of the novel feature and conventional features for motion pattern recognition using EMG signals, which included time-domain and frequency-domain features, was compared during dynamic and isometric muscle contractions. Experiments were conducted using an exoskeleton robotic arm to aid users in generating EMG signals of designated motion patterns. Among the features tested, the STFT-ranking feature yielded an accuracy rate exceeding 90% when the EMG signals used in the training and validation feature data sets were of the same type of muscle contraction. After examining the STFT-ranking feature projected onto the PCA space, the STFT-ranking feature was determined to offer more satisfactory performance than the other features tested for motion pattern recognition, because the feature data it collected from various motion patterns were more separable. The experimental results also revealed that it is preferable that EMG signals from the same type of muscle contraction, whether dynamic or isometric, are consistently used in both the training and validation (control) phases. Inconsistent EMG signals in the training and validation phases yielded a negative effect on motion pattern recognition performance. The methodology developed in this study has potential applications in exoskeleton robot control and rehabilitation. © 2014 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Assessment of Muscle Fatigue for FES Research Studies

Background: Muscle fatigue is an important issue in neuromuscular rehabilitation. Better control of this phenomenon would result in better prevention of its consequent physiological damages.Objective: To provide a mathematical representation of muscle fatigue as a function of time.Methods: We conducted this study by combining the EMG-based estimation methods of muscle activation with the availa...

متن کامل

The effect of isometric contractions of upper and lower limb muscles on the ultrasonic thickness of the transversus abdominis muscle

Background: The transverse abdominis (TrA) muscle is one of the most important muscles that contribute to the stability of the lumbar spine. Strengthening of trunk muscles that have a significant role in trunk stability is very important in the field of professional sport, sport medicine and rehabilitation of patient with low back pain (LBP). Identifying the exercises that can improve the stren...

متن کامل

Beta- and gamma-range human lower limb corticomuscular coherence

Coherence between electroencephalography (EEG) recorded on the scalp above the motor cortex and electromyography (EMG) recorded on the skin of the limbs is thought to reflect corticospinal coupling between motor cortex and muscle motor units. Beta-range (13-30 Hz) corticomuscular coherence has been extensively documented during static force output while gamma-range (31-45 Hz) coherence has been...

متن کامل

Evaluating Spatial Characteristics of Upper-Limb Movements from EMG Signals

Stroke is a major cause of disability, usually causing hemiplegic damage on the motor abilities of the patient. Stroke rehabilitation seeks restoring normal motion on the affected limb. However, ‘normality’ of movements is usually assessed by clinical and functional tests, without considering how the motor system responds to therapy. We hypothesized that electromyographic (EMG) recordings could...

متن کامل

Muscle activation during low-intensity muscle contractions with varying levels of external limb compression.

The purpose was to investigate muscle activation during low- intensity muscle contractions with various levels of external limb compression to reduce muscle perfusion/outflow. A series of unilateral elbow flexion muscle contractions (30 repetitive contractions followed by 3 sets x 15 contractions) was performed at 20% of 1RM with varying levels of external compression (0 (without compression), ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomed. Signal Proc. and Control

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2014