Catheter ablation of atrial tachyarrhythmias causing inappropriate implantable cardioverter-defibrillator shocks.

نویسندگان

  • Shinsuke Miyazaki
  • Hiroshi Taniguchi
  • Shigeki Kusa
  • Yuki Komatsu
  • Noboru Ichihara
  • Takamitsu Takagi
  • Jin Iwasawa
  • Akio Kuroi
  • Hiroaki Nakamura
  • Hitoshi Hachiya
  • Kenzo Hirao
  • Yoshito Iesaka
چکیده

AIMS Inappropriate shocks have been an important issue post-implantable cardioverter-defibrillator (ICD) implantation. Moreover, inappropriate ICD shocks are associated with increased mortality. The objective of this study was to evaluate the feasibility of catheter ablation therapy for atrial tachyarrhythmias (ATa) responsible for inappropriate ICD shocks. METHODS AND RESULTS Among 108 consecutive patients who underwent ICD implantations, 22, 5, and 3 experienced inappropriate ICD shocks due to ATa, sinus tachycardia, and T-wave oversensing, respectively. Among the 22 patients with ATa, 18 patients (55 ± 10 years, 15 men, structural heart disease in 9) underwent catheter ablation of ATa causing inappropriate shocks. The median duration between the ICD implantation and first inappropriate shock was 10.0 (3.0-24.5) months. The ATa were atrial fibrillation (AF), atrial flutter (AFL), and atrioventricular nodal reentrant tachycardia in 14, 2, and 2 patients, respectively. One patient underwent an atrioventricular nodal ablation for persistent AF associated with a venous anomaly. Among 13 patients who underwent pulmonary vein antrum isolation, 10 (76.9%) were free from AF for a median of 21.0 (13-37.3) months after an average of 1.3 ± 0.5 procedures. In four patients with AFL or a supraventricular tachycardia, none had any arrhythmia recurrence for a median of 6.0 (3.3-93.5) months after a cavotricuspid isthmus or slow pathway ablation, respectively. There were no procedural complications. During the median follow-up of 19.0 (9.5-37.3) months after the last procedure, no patients experienced any inappropriate shocks. CONCLUSION Catheter ablation is a feasible therapeutic option for treating ATa responsible for inappropriate shock(s) in patients with ICD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in Arrhythmia and Electrophysiology Minimizing Inappropriate or “Unnecessary” Implantable Cardioverter-Defibrillator Shocks Appropriate Programming

Life-saving shocks are the raisons d’être of implantable cardioverter-defibrillators (ICDs). Paradoxically, shocks also cause much of the morbidity associated with ICDs. Consistently, shocks reduce quality of life,1,2 and rarely, they may cause proarrhythmia.3,4 Additionally, shocks have been reported to be associated with excess mortality.5 Experts disagree about whether shocks are responsible...

متن کامل

Trouble Shooting of ICD Therapy: Inappropriate Shock

Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...

متن کامل

Minimizing inappropriate or "unnecessary" implantable cardioverter-defibrillator shocks: appropriate programming.

Life-saving shocks are the raisons d’être of implantable cardioverter-defibrillators (ICDs). Paradoxically, shocks also cause much of the morbidity associated with ICDs. Consistently, shocks reduce quality of life,1,2 and rarely, they may cause proarrhythmia.3,4 Additionally, shocks have been reported to be associated with excess mortality.5 Experts disagree about whether shocks are responsible...

متن کامل

Pathogenesis of Ventricular Tachyarrhythmias

• Volume 120 • Number 4 www.anesthesia-analgesia.org 737 Copyright © 2015 International Anesthesia Research Society DOI: 10.1213/ANE.0000000000000556 During the past few decades, cardiac electrophysiology (EP) has evolved from a specialty that primarily implanted simple pulse generators (pacemakers) for bradycardia therapy to a specialty with an expanded practice in detecting and terminating ar...

متن کامل

Oversensing of atrial fibrillatory waves in a subcutaneous implantable cardioverter-defibrillator

Introduction Implantable cardioverter-defibrillators (ICDs) have been shown to improve survival in patients with ischemic or nonischemic cardiomyopathy when used for primary and secondary prevention settings. The limitations of transvenous ICDs include postimplant adverse events, defibrillator lead failure, and inappropriate shocks for atrial tachyarrhythmias due to fast ventricular response ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2015