Perfusion scintigraphy versus 256-slice CT angiography in pregnant patients suspected of pulmonary embolism: comparison of radiation risks.

نویسندگان

  • Kostas Perisinakis
  • Ioannis Seimenis
  • Antonis Tzedakis
  • John Damilakis
چکیده

UNLABELLED One aim of the current study was to determine normalized dose data for maternal radiosensitive organs and embryo/fetus from 256-slice CT pulmonary angiography (CTPA) performed on pregnant patients suspected of having pulmonary embolism. A second aim was to provide reliable maternal and fetal doses and associated radiation cancer risk estimates from 256-slice CTPA and lung perfusion scintigraphy (LPS) for comparison. METHODS Mathematic anthropomorphic phantoms were generated to simulate the average woman at early pregnancy and at the third, sixth, and ninth months of gestation. In each phantom, 0-3 additional 1.5-cm-thick fat tissue layers were added to derive 4 phantoms representing pregnant women with different body sizes. Monte Carlo methods were used to simulate low-dose 256-slice CTPA exposures on each of the 16 generated phantoms. Normalized organ and embryo/fetal dose data were derived for exposures at 80, 100, and 120 kV. Maternal effective dose and embryo/fetal dose from 256-slice CTPA and associated lifetime attributable risks of radiation cancer were determined for different body sizes and gestational stages and compared with corresponding data from LPS. RESULTS For an average-sized pregnant patient at the first trimester, the 256-slice CTPA exposure resulted in a maternal effective dose of 1 mSv and an embryo/fetal dose of 0.05 mGy. However, maternal effective dose considerably increased with body size, whereas embryo/fetal dose increased with both body size and gestational stage. Compared with LPS, low-dose CTPA to an average-sized pregnant patient resulted in a 30% higher maternal effective dose but a 3.4-6 times lower embryo/fetal dose. Nevertheless, LPS was associated with less aggregated radiation risk for an average-sized pregnant patient, with the difference from CTPA being increased further for larger patients. CONCLUSION Compared with CTPA performed with a modern wide-area CT scanner, LPS remains comparatively more dose-efficient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Imaging for suspected pulmonary embolism in pregnancy—what about the fetal dose? A comprehensive review of the literature

OBJECTIVE: To give a comprehensive overview of fetal doses reported in the literature when imaging the pregnant woman with suspected pulmonary embolism (PE). METHODS: A comprehensive literature search in the PubMed, MEDLINE and EMBASE databases yielded a total of 1,687 papers that were included in the analysis and have been analysed with regard to fetal dose in suspected PE radiological imagin...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

Diagnosis of Pulmonary Embolus

In patients with suspected pulmonary embolism, posterior/anterior and lateral chest X-rays are recommended as an initial imaging examination because they may reveal an alternate diagnosis and obviate the need for further imaging. If the chest X-ray is negative and the patient has a D-dimer level over an age-adjusted threshold, CT pulmonary angiography (CTPA) is the examination of choice. Ventil...

متن کامل

CT pulmonary angiography versus ventilation-perfusion scintigraphy in pregnancy: implications from a UK survey of doctors' knowledge of radiation exposure.

PURPOSE To prospectively investigate the fetal dosimetry knowledge of health care professionals involved in the management of pulmonary embolism. MATERIALS AND METHODS One hundred sixty-one health care professionals consented to participate in this study, which had ethical board approval. The individuals surveyed were from 14 hospitals (seven university and seven community hospitals) in the U...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 55 8  شماره 

صفحات  -

تاریخ انتشار 2014