Silicon quantum dot sensors for an explosive taggant, 2,3-dimethyl-2,3-dinitrobutane (DMNB).

نویسندگان

  • Jin Soo Kim
  • Bomin Cho
  • Soo Gyeong Cho
  • Honglae Sohn
چکیده

Silicon quantum dots obtained by the reaction of magnesium silicide with ethylenediamine dihydrochloride were utilized to investigate the sensing mechanism and sensitivity for DMNB detection applications. Sensing DMNB provided us with evidence that Si QDs with a higher lying conduction band have better sensitivity compared to CdSe QDs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amplifying fluorescent polymer sensors for the explosives taggant 2,3-dimethyl-2,3-dinitrobutane (DMNB).

Structural and electronic effects on the efficiency of DMNB detection with fluorescent conjugated polymers are described.

متن کامل

Fragmentation pathways of 2,3-dimethyl-2,3-dinitrobutane cations in the gas phase.

2,3-Dimethyl-2,3-dinitrobutane (DMNB) is an explosive taggant added to plastic explosives during manufacture making them more susceptible to vapour-phase detection systems. In this study, the formation and detection of gas-phase [M+H](+), [M+Li](+), [M+NH(4)](+) and [M+Na](+) adducts of DMNB was achieved using electrospray ionisation on a triple quadrupole mass spectrometer. The [M+H](+) ion ab...

متن کامل

A nanoparticle-coated chemiresistor array as a microscale gas chromatograph detector for explosive marker compounds: flow rate and temperature effects.

The effects of flow rate and temperature on the performance of a microscale gas chromatographic (μGC) detector consisting of a chemiresistor (CR) array coated with different thiolate-monolayer-protected gold nanoparticles (MPNs) are described with respect to the analysis of three gas-phase markers of the explosive trinitrotoluene (TNT): 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT)...

متن کامل

Detecting Trace Explosives and Formulations Using Laser Electrospray Mass Spectrometry

Mass analysis using laser electrospray mass spectrometry (LEMS) is demonstrated for the detection of trace samples of explosives at atmospheric pressure directly from a substrate. A non-resonant femtosecond duration laser pulse vaporizes native samples at atmospheric pressure for subsequent electrospray ionization and transfer into a mass spectrometer. LEMS was used to detect < 1 µg of 2,3-dime...

متن کامل

Identification of explosives and explosive formulations using laser electrospray mass spectrometry.

Mass analysis is demonstrated for the detection of sub-microgram quantities of explosive samples on a metallic surface at atmospheric pressure using laser electrospray mass spectrometry (LEMS). A non-resonant femtosecond duration laser pulse vaporizes native samples for subsequent electrospray ionization and transfer into a time-of-flight mass spectrometer. LEMS was used to detect 2,3-dimethyl-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 52 53  شماره 

صفحات  -

تاریخ انتشار 2016