Can dynamic krypton-81m imaging separate regional ventilation and volume?

نویسندگان

  • M F Lythgoe
  • H Davies
  • A Kuba
  • M Toth-Abonyi
  • I Gordon
چکیده

This study explores the assumption that 81mKr static images represent regional ventilation. Dynamic acquisition of 81mKr ventilation images permits creation of time-activity curves and the possible separation of the confounding influences of ventilation and volume. By using a two-compartment gas mixing lung phantom, the results demonstrate that both total and tidal 81mKr are closely related to regional ventilation. In 61 children and 15 adult volunteers, there was good agreement between fractional ventilation assessed by total and tidal 81mKr. The dynamic steady-state ventilation image can be analyzed to separate tidally exchanged and resident 81mKr. This may allow regional ventilation to be distinguished from regional volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patterns of disturbed myocardial perfusion in patients with coronary artery disease. Regional myocardial perfusion in angina pectoris.

Fifty patients who presented with angina pectoris were studied to examine the disturbances of regional myocardial perfusion during stress. Each patient underwent 16-point precordial mapping of the ECG during an exercise test, and coronary and left ventricular angiography. Regional myocardial perfusion was assessed using an atrial pacing test and a short-lived radionuclide, krypton-81m. Eleven p...

متن کامل

Investigating the small lung: which imaging procedure?

Ventilation and perfusion radionuclide lung scans, using krypton 81m and technetium-99m macroaggregates, were performed together with a variety of other imaging procedures in 18 children aged between 1 week and 13 years in whom radiology had shown a small lung. Radionuclide scans provided an assessment of regional ventilation and perfusion unobtainable by other means, and 4 main categories of d...

متن کامل

Krypton - 81 m / Technetium - 99 m Lung Scintigraphy Significance of Single Ventilation / Perfusion Mismatches

J Nucl Med. Joel M. Rosen, Christopher J. Palestro, David Markowitz and Philip O. Alderson Krypton-81m/Technetium-99m Lung Scintigraphy Significance of Single Ventilation/Perfusion Mismatches in http://jnm.snmjournals.org/content/27/3/361 This article and updated information are available at: http://jnm.snmjournals.org/site/subscriptions/online.xhtml Information about subscriptions to JNM can b...

متن کامل

Regional ventilation studies with Kr-81m and Xe-133: a comparative analysis.

Krypton-81m and Xe-133 ventilation scintigrams, and particulate per fusion scintigrams with Tc-99m, were obtained on the same day in 41 pa tients. Of 14 studies demonstrating pulmonary embolism, Kr-81m corn plernented the perfusion study better than Xe-133 in seven and was judged essential for that diagnosis in two. Xenon-133 was better in none. On the other hand, in 29 studies with obstructive...

متن کامل

Tomography of regional ventilation and perfusion using krypton 81m in normal subjects and asthmatic patients.

Single photon emission computed tomography, a rotating gamma camera, and continuous inhalation or infusion of krypton 81m (half life 13 seconds) were used to measure regional ventilation (V), perfusion (Q), and ventilation-perfusion (V/Q) ratios in five normal subjects in supine, prone, and lateral decubitus postures and in three asthmatic patients (supine posture only) before and after inhalat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 1992