Ficoll is not a rigid sphere.

نویسندگان

  • William H Fissell
  • Sargum Manley
  • Anna Dubnisheva
  • Jeffrey Glass
  • Jeffrey Magistrelli
  • Abigail N Eldridge
  • Aaron J Fleischman
  • Andrew L Zydney
  • Shuvo Roy
چکیده

Polydisperse Ficoll mixtures have been used to explore glomerular sieving. Ficoll appears to be neither absorbed nor secreted by the renal tubule, and so urinary Ficoll concentrations reflect only the glomerular filtration barrier. The literature is contradictory regarding Ficoll's behavior as an idealized spherical solute. Further definition of Ficoll transport will inform interpretation of in vivo results. Flat-sheet membranes comprising a uniform array of slit pores measuring 8 nm by 45 mum were perfused with FITC-labeled Ficoll 70 and BSA. Ficoll and BSA concentrations were quantified by gel-permeation chromatography and Bradford assay, respectively. BSA and Ficoll molecules with diameters equal to approximately half of the slit pore width displayed hindered transport in agreement with modeled rigid sphere transport through slit-shaped pores. Ficoll molecules larger than approximately 0.65 slit width displayed transport rates in excess of predictions. Ficoll molecules with Stokes-Einstein diameters greater than the pore dimension were observed in permeate samples. We present data for Ficoll filtration through a novel array of well-defined pores, which illustrate that Ficoll is well modeled as an ideal sphere in one size domain, but the model breaks down as molecular diameter approaches pore size. These data inform the present debate regarding glomerular filtration and affect conclusions drawn from the use of Ficoll as a tracer molecule. The apparent hyperpermeability of Ficoll through slit-shaped pores suggests that further modeling incorporating deformation of the molecule is necessary when using Ficoll solutions to characterize membranes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Size and conformation of Ficoll as determined by size-exclusion chromatography followed by multiangle light scattering.

The characteristics of the glomerular filtration barrier (GFB) are challenging to measure, as macromolecular solutes in blood may be metabolized or transported by various cells in the kidney. Urinary solute concentrations generally reflect the cumulative influence of multiple transport processes rather than the intrinsic behavior of the GFB alone. Synthetic tracer molecules which are not secret...

متن کامل

Ficoll and dextran vs. globular proteins as probes for testing glomerular permselectivity: effects of molecular size, shape, charge, and deformability.

Polydisperse mixtures of dextran or Ficoll have been frequently used as molecular probes for studies of glomerular permselectivity because they are largely inert and not processed (reabsorbed) by the proximal tubules. However, dextrans are linear, flexible molecules, which apparently are hyperpermeable across the glomerular barrier. By contrast, the Ficoll molecule is almost spherical. Still, t...

متن کامل

Flattening of a deformable sphere by a rigid sphere during transient thermo-mechanical contact

A finite element model is developed to study the transient thermo-mechanical contact between a rigid sphere and an elastic–plastic sphere. Interference and tangential displacement are applied to the rigid sphere while the elastic–plastic sphere is stationary. The radius of the rigid sphere is larger than that of the elastic–plastic sphere to model flattening. Universal solutions are obtained fo...

متن کامل

Computations of the Directivity of Spherical Microphone Arrays

The aim of this research is to create a microphone array on a rigid sphere that could be used for teleconferences and for recording of music with the aim of five-channel loudspeaker surround sound reproduction. Experiments were undertaken, within a MATLAB environment, by running computer simulations that tested the directivity of a rigid sphere microphone array in both near and far field. The s...

متن کامل

High level Ab inito bench mark computaions on weak interactions (H2)2 dimer revisited

The Potential Energy Surface PES of (H2)2 dimer has been investigated, using five simple rigid rotor models. These models are called: head to head, symmetric side to side, L , steplike and T model. All calculations were done at two levels of ab initio  methods: MP2(Full) and QCISD (T,Full) using cc-pVTZ basis set at singlet state of spin multiplicity. The results of scanning PES were then fitte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Renal physiology

دوره 293 4  شماره 

صفحات  -

تاریخ انتشار 2007