Comparison between overground and dynamometer manual wheelchair propulsion.
نویسندگان
چکیده
Laboratory-based simulators afford many advantages for studying physiology and biomechanics; however, they may not perfectly mimic wheelchair propulsion over natural surfaces. The goal of this study was to compare kinetic and temporal parameters between propulsion overground on a tile surface and on a dynamometer. Twenty-four experienced manual wheelchair users propelled at a self-selected speed on smooth, level tile and a dynamometer while kinetic data were collected using an instrumented wheel. A Pearson correlation test was used to examine the relationship between propulsion variables obtained on the dynamometer and the overground condition. Ensemble resultant force and moment curves were compared using cross-correlation and qualitative analysis of curve shape. User biomechanics were correlated (R ranging from 0.41 to 0.83) between surfaces. Overall, findings suggest that although the dynamometer does not perfectly emulate overground propulsion, wheelchair users were consistent with the direction and amount of force applied, the time peak force was reached, push angle, and their stroke frequency between conditions.
منابع مشابه
To What Extent Are Spatiotemporal and Handrim Kinetic Parameters Comparable between Overground and Wheelchair Simulator Propulsions among Long-term Manual Wheelchair Users?
A repeated cross-sectional research design was used in this study to compare propulsion biomechanics on a newly developed wheelchair simulator to overground natural propulsion. Seventeen individuals (15 men and 2 women) with spinal cord injury between T4 and T12 completed two 20-meter propulsion trials on a tiled surface and two 1-minute propulsion sessions on the simulator. The main outcome me...
متن کاملA New Manual Wheelchair Simulator with Haptic Biofeedback to Improve Propulsion Effectiveness
This study describes a new simulator that provides haptic biofeedback to help manual wheelchair users gain a more effective propulsion pattern. Propulsion effectiveness is measured using the mechanical effective force (MEF). The simulator implements a dynamic model that replicates overground propulsion conditions. Haptic biofeedback increases the feeling of rolling resistance if the user’s MEF ...
متن کاملMultisite comparison of wheelchair propulsion kinetics in persons with paraplegia.
A multisite collaborative study is being conducted on the association between propulsion biomechanics and upper-limb injuries. This substudy compared subject characteristics and pushrim kinetics across three sites and identified early on in the main study any differences that could affect interpretation of the findings or data pooling. A total of 42 manual wheelchair users with paraplegia (14 f...
متن کاملDesign and Modification of One Arm Driven Manual Hemiplegic Wheelchair
This paper presents design modification to the existing standard wheelchair by incorporating an improved propulsion system and also braking and tilting systems that allow its full control with only one hand. The proposed design has the propulsion system with a chain drive powered through a four-bar linkage driven by the main handle. The desired direction of motion is obtained by moving the leve...
متن کاملShoulder Pain and Cycle to Cycle Kinematic Spatial Variability during Recovery Phase in Manual Wheelchair Users: A Pilot Investigation
UNLABELLED Wheelchair propulsion plays a significant role in the development of shoulder pain in manual wheelchair users (MWU). However wheelchair propulsion metrics related to shoulder pain are not clearly understood. This investigation examined intra-individual kinematic spatial variability during semi-circular wheelchair propulsion as a function of shoulder pain in MWU. Data from 10 experien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied biomechanics
دوره 28 4 شماره
صفحات -
تاریخ انتشار 2012