A randomized controlled study comparing pain experience between a newly designed needle with a thin tip and a standard needle for oocyte aspiration

نویسندگان

  • M. Wikland
  • S. Blad
  • L. Bungum
  • T. Hillensjö
  • P.O. Karlström
  • S. Nilsson
چکیده

UNLABELLED BACKGROUND; Ultrasound-guided transvaginal oocyte retrieval is often performed under local anaesthesia on an outpatient basis. The objective of this study was to compare the overall pain experience of a newly designed reduced needle (RN) compared with a thicker standard needle (SN). METHODS A prospective, randomized, multi-centre study was performed at four different clinics from June to December 2009. The oocyte aspiration was performed under local anaesthesia, either with a needle with a reduced diameter (0.9 mm) for the last 50 mm from the tip (RN) or with a SN (1.4 mm). A total of 257 patients were randomized (RN: n = 129; SN: n = 128). The primary endpoint was the overall pain experience self-assessed and registered by the patient on a visual analogue scale (VAS 0 mm = no pain to 100 mm = unbearable pain) immediately after the oocyte retrieval. Secondary end-points such as vaginal bleeding and several embryological parameters were also registered. RESULTS The overall pain during the oocyte retrieval procedure was significantly lower in the RN group than in the SN group (mean 21.0 mm, SD 17.5 mm and median 19.0 mm versus mean 26.0 mm, SD 19.9 mm and median 24.0 mm; P = 0.040, difference between groups mean-5.0 mm, 95% CI: 9.7 to-0.4). This was also true when adjusting for baseline characteristics such as number of follicles, number of previous oocyte pick-up, body mass index and age, by a multiple linear regression analysis. Significantly more patients (40 of 126) had less than expected vaginal bleeding in the RN group when compared with the SN group (24 of 124; 32 versus 19%; P = 0.03 and 95% CI 1.7-23.0%). No differences were found between the two needles with regard to additional i.v. analgesia, aspiration time, oocyte recovery, fertilization, cleavage rate, number of good quality embryos, number of embryos for freezing and pregnancy rate. CONCLUSIONS Oocyte aspiration performed with the newly designed thinner-tipped needle resulted in significantly less overall pain and less vaginal bleeding, without prolonging the retrieval procedure or influence the oocyte recovery rate, when compared with a SN. Clinicaltrials.gov: NCT00924885.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the effectiveness of local anesthesia before thyroid fine needle biopsy considering the size of the nodule

Background: Fine needle aspiration biopsy (FNAB) is usually used to distinguish the malignant and benign nodules. Applying a biopsy needle evokes a sense of fear and pain in the patients. Although some studies refute the usefulness of local anesthesia (LA) prior to fine needle aspiration biopsy, it is still debatable. This prospective cross-sectional study intended to evaluate the effect of LA ...

متن کامل

The Effect of a Newly Designed Needle on the Pain and Bleeding of Patients During Oocyte Retrieval of a Single Follicle

BACKGROUND The purpose of this study was to evaluate the effect of needle type on pain and bleeding during oocyte pick-up (OPU). METHODS From May through November 2013, patients undergoing OPU from a single follicle without any analgesic treatment were including this study. Eligible patients (n=75) were randomized 1:1 to undergo the procedure with either a reduced needle (17 gauge body, 20 ga...

متن کامل

A Prospective Randomized Controlled Study Comparing EUS Sonopsy CY(R) and 22-gauge Biopsy Needles for Endoscopic Ultrasound-guided Fine-Needle Aspiration of Solid Pancreatic Mass Lesions.

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a standard procedure for precise histological diagnosis of pancreas tumors, but it is sometimes difficult to obtain adequate specimens. EUS Sonopsy CY® is a newly designed needle with original features. This randomized study will compare the tissue collection rate of EUS Sonopsy CY® to that of a conventional needle in EUS-FNA. The...

متن کامل

Effect of topical ginger on the pain of venipuncture in hemodialysis patients: A randomized controlled trial

Background & Aim: Pain during vascular access is an integral part of the life of hemodialysis patients. The aim of this study was to determine the effect of topical ginger on pain following needle insertion into the arteriovenous fistula in hemodialysis patients. Methods & Materials: In this clinical trial, 100 hemodialysis patients were selected from two hospitals in Shahroud in 2019 and were...

متن کامل

Diagnostic Efficacy of Fine Needle Aspiration in Parotid Mass

Introduction: The preoperative diagnostic evaluation of the parotid lesion is a valuable aid in planning the operation and the approach to intervention. Among different diagnostic tools, Fine Needle Aspiration has a key role. However, the exact efficacy of this technique in our center had not been thoroughly investigated. Materials and Methods: Between January 2000 and June 2007 a subset of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2011