Unit-specific calibration of Actigraph accelerometers in a mechanical setup – Is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field

نویسندگان

  • Niels C Moeller
  • Lars Korsholm
  • Peter L Kristensen
  • Lars B Andersen
  • Niels Wedderkopp
  • Karsten Froberg
چکیده

BACKGROUND Potentially, unit-specific in-vitro calibration of accelerometers could increase field data quality and study power. However, reduced inter-unit variability would only be important if random instrument variability contributes considerably to the total variation in field data. Therefore, the primary aim of this study was to calculate and apply unit-specific calibration factors in multiple accelerometers in order to examine the impact on random output variation caused by inter-instrument variability. METHODS Instrument-specific calibration factors were estimated in 25 MTI- and 53 CSA accelerometers in a mechanical setup using four different settings varying in frequencies and/or amplitudes. Calibration effect was analysed by comparing raw and calibrated data after applying unit-specific calibration factors to data obtained during quality checks in a mechanical setup and to data collected during free living conditions. RESULTS Calibration reduced inter-instrument variability considerably in the mechanical setup, both in the MTI instruments (raw SDbetween units = 195 counts*min-1 vs. calibrated SDbetween units = 65 counts*min-1) and in the CSA instruments (raw SDbetween units = 343 counts*min-1 vs. calibrated SDbetween units = 67 counts*min-1). However, the effect of applying the derived calibration to children's and adolescents' free living physical activity data did not alter the coefficient of variation (CV) (children: CVraw = 30.2% vs. CVcalibrated = 30.4%, adolescents: CVraw = 36.3% vs. CVcalibrated = 35.7%). High correlations (r = 0.99 & r = 0.98, respectively) were observed between raw and calibrated field data, and the proportion of the total variation caused by the MTI- and CSA monitor was estimated to be only 1.1% and 4.2%, respectively. Compared to the CSA instruments, a significantly increased (9.95%) mean acceleration response was observed post hoc in the batch of MTI instruments, in which a significantly reduced inter-instrumental reliability was observed over time. CONCLUSION The application of unit-specific calibration factors to data collected during free living conditions had no apparent effect on inter-instrument variability. In all probability, the effect of technical calibration was primarily attenuated in the field by other more dominant sources of variation. However, routine technical assessments are still very important for determining the acceleration responses in the batch of instruments being used and, if performed after every field use, for preventing decidedly broken instruments from being returned into the field repeatedly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector

Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...

متن کامل

Technical guide to Set Up a Spectral Solar Direct Normal Irradiance Permanent Station: Study Area- Hannover, Germany

The spectral Direct Normal Irradiance (SDNI) is a basic radiometric quantity from which many other quantities can be derived. It provides not only information about the spectral and distribution of the direct solar radiation reaching a particular location. Accurate knowledge about the spectral direct irradiance shall enable us to gain new scientific results in the: determination of cloud effect...

متن کامل

The Effect of Spatial Variability and Anisotropy of Soils on Bearing Capacity of Shallow Foundations

Naturally occurred soil deposits inherit heterogeneity and anisotropy in their strength properties. The main purpose of this paper is to model the soil stratum with anisotropy consideration and spatially varying undrained shear strength by using random field theory coupled with finite difference numerical analysis to evaluate their effect on the bearing capacity of the shallow foundations. In t...

متن کامل

Behavior of Piled Raft Foundation on Heterogeneous Clay Deposits Using Random Field Theory

In the case of problematic soils and tall buildings where the design requirements cannot be satisfied merely by a raft foundation, it is of common practice to improve the raft performance by adding a number of piles so that the ultimate load capacity and settlement behavior can be enhanced. In this study, the effect of spatial variability of soil parameters on the bearing capacity of piled raft...

متن کامل

Improvement of position measurement for 6R robot using magnetic encoder AS5045

Recording the variation of joint angles as a feedback to the control unit is frequent in articulated arms. In this paper, magnetic sensor AS5045, which is a contactless encoder, is employed to measure joint angles of 6R robot and the performance of that is examined. The sensor has a low volume, two digital outputs and provides a high resolution measurement for users; furthermore its zero positi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Medical Research Methodology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008