[Comparative study of thoracic approaches in atrial septal defect closure].

نویسندگان

  • Juan-Miguel Gil-Jaurena
  • Marcos Murtra
  • Arturo Gonçalves
  • Luis Miró
  • Ramón Vilá
  • Manel García-Górriz
چکیده

Our early experience in approaching ASD by right thoracotomy as opposed to midline sternotomy is presented. Between July 2000 and December 2001, 15 patients (group A) were operated by right thoracotomy. Mean age of patients was 8.6 years and mean weight was 31.6 kg. In the same period, midline sternotomy was used in 16 patients (group B). Mean age was 4.7 years and weight was 16.5 kg. The duration of the procedure, by-pass, and aortic cross-clamping were similar. Bleeding was 265 ml (8.4 ml/kg) in group A, and 152 ml (9.2 ml/kg) in group B. The duration of the ICU stay and time of discharge were 2.4 days and 6 days in group A, and 2.23 days and 6.87 days in group B, respectively. No significant differences were found in ASD closure by thoracotomy and sternotomy. The cosmetic appearance acceptance of right thoracotomy was excellent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Totally Thoracoscopic Ablation for Treatment of Atrial Fibrillation after Atrial Septal Defect Device Closure

Atrial septal defect (ASD) is one of the most common congenital heart defects in adults. Surgical repair is the most common treatment approach, but device closure has recently become widely performed in accordance with the trend toward less invasive surgical approaches. Although surgery is recommended when ASD is accompanied by atrial fibrillation, this study reports a case in which a complete ...

متن کامل

Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder

PURPOSE For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS From November 2009 until November 2011, cardiac computed to...

متن کامل

Totally endoscopic removal of dislocated atrial septal defect - closure devices.

With interest, we read the article by Sarris et al. that demonstrated a number of considerable early and late complications of interventionally placed atrial septal defect (ASD) closure devices [1]. A series of 56 patients is reported. It would be important to know how many interventionally implanted ASD-closure devices were implanted in these centers. Another question is which surgical access ...

متن کامل

Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

OBJECTIVE In this study, we tested 3 techniques of atrial septal defect closure under real-time 3-dimensional echocardiography guidance in a swine model. METHODS The operations were conducted under the sole guidance of a modified real-time 3-dimensional echocardiography guidance system with a x4 matrix transducer (Sonos 7500, Philips Medical Systems, Andover, Mass). Eighteen swine were anesth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 55 11  شماره 

صفحات  -

تاریخ انتشار 2002