A simultaneous electrochemical impedance and quartz crystal microbalance study on antihuman immunoglobulin G adsorption and human immunoglobulin G reaction.

نویسندگان

  • Hua He
  • Qingji Xie
  • Youyu Zhang
  • Shouzhuo Yao
چکیده

The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric quartz crystal (PQC) as well as electrochemical impedance (EI) parameters were measured and discussed. The standard heterogeneous rate constants of the ferricyanide/ferrocyanide couple before and after the antibody adsorption and antibody-antigen reactions were determined. The results show that the amount for antibody adsorption was the greatest on the most hydrophobic (1-dodecanethiol-modified) surface, while the antibody bioactivity was almost identical on the three kinds of surfaces. Two parameters simultaneously obtained, Deltaf and DeltaC(s) (interfacial capacitance), have been used for the first time to estimate both the association constant of the immunoreaction and the valence of antigen with satisfactory results. The proposed method may find wide application in interfacial biochemistry studies for its advantages in providing real-time multidimensional piezoelectric and electrochemical impedance information.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generic method for attaching biomolecules via avidin-biotin complexes immobilized on films of regenerated and nanofibrillar cellulose.

We investigated the adsorption and chemical conjugation of avidin and its deglycosylated form, neutravidin, on films of regenerated and nanofibrillar cellulose. The dynamics and extent of biomolecular attachment were monitored in situ by quartz crystal microbalance microgravimetry and ex situ via surface analyses with atomic force microscopy and X-ray photoelectron spectroscopy. The installatio...

متن کامل

Mechanism of formation and construction of self-assembled myoglobin/hyaluronic acid multilayer films: an electrochemical QCM, impedance, and AFM study.

Self-assembled multilayer films of hyaluronic acid (HA) and the protein myoglobin (Mb) were built up layer by layer on Au covered quartz crystal microbalance (AuQCM) electrode substrates. Film formation and growth were monitored by an electrochemical quartz crystal microbalance (EQCM), and the step-by-step construction was investigated through quantification of the mass variation corresponding ...

متن کامل

Human immunoglobulin adsorption investigated by means of quartz crystal microbalance dissipation, atomic force microscopy, surface acoustic wave, and surface plasmon resonance techniques.

Time-resolved adsorption behavior of a human immunoglobin G (hIgG) protein on a hydrophobized gold surface is investigated using multitechniques: quartz crystal microbalance/dissipation (QCM-D) technique; combined surface plasmon resonance (SPR) and Love mode surface acoustic wave (SAW) technique; combined QCM-D and atomic force microscopy (AFM) technique. The adsorbed hIgG forms interfacial st...

متن کامل

Anti-rabbit immunoglobulin G detection in complex medium by PM-RAIRS and QCM Influence of the antibody immobilisation method.

Two antibody immobilisation procedures were compared to set up an immunosensor for goat anti-rabbit immunoglobulin (anti-rIgG), i.e. rIgG covalently bound or immobilised via affinity to protein A (PrA). In both cases, the first layer of protein was covalently bound to a mixed self-assembled monolayer (SAM) of mercaptoundecanoic acid (MUA) and mercaptohexanol (C6OH) on a gold surface. The elabor...

متن کامل

Modification of cellulose films by adsorption of CMC and chitosan for controlled attachment of biomolecules.

The adsorption of human immunoglobulin G (hIgG) and bovine serum albumin (BSA) on cellulose supports were investigated. The dynamics and extent of related adsorption processes were monitored by surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D). Amine groups were installed on the cellulose substrate by adsorption of chitosan from aqueous solution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biochemical and biophysical methods

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2005