Calibrated cusp sizers to facilitate aortic valve repair: development and clinical application.

نویسنده

  • Mohammad Bashar Izzat
چکیده

Based on the natural mathematical relationships between the components of the human tri-leaflet aortic valve, new calibrated cusp sizers were developed in order to facilitate aortic valve assessment in the operating room and enhance the chance for a perfect restoration of aortic valve competence. These sizers were used clinically to guide the implementation of established aortic valve repair techniques in 10 consecutive patients with severe aortic valve regurgitation. Valve repair was successful in all cases, and at a median follow-up was 5.5 months, aortic valve function remained stable, with aortic regurgitation ≤1+ in every patient and no significant gradient across the aortic valves. This preliminary clinical experience indicates that the calibrated cusp sizers can provide reliable insight into the mechanism of aortic valve insufficiency, and can guide aortic valve repair techniques successfully. We hope that the simplicity and reproducibility of this method would assist in its dissemination and further increase the percentage of aortic valves that are repaired when compared with current practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

A standardized approach to aortic valve repair is described associating a physiological remodeling of the root, with resuspension of cusp effective height and a subvalvular aortic annuloplasty using an external expansible ring. This device achieves a complete calibrated annuloplasty, in order to increase cups coaptation height and protect the repair. This is a video-atlas describing the surgica...

متن کامل

Toward predictable repair of regurgitant aortic valves: a systematic morphology-directed approach to bicommissural repair.

OBJECTIVES Our purpose was to investigate a new approach to bicommissural repair of regurgitant aortic valves. BACKGROUND Repair of regurgitant aortic valves is not widely accepted, but interest is increasing, particularly for bicuspid valves. We hypothesize that a systematic, segmental approach to morphology and corresponding morphology-directed repair will improve decision making and succes...

متن کامل

Cusp height in aortic valves.

OBJECTIVES Successful aortic valve repair must normalize cusp and root dimensions. Limited information is available on the normal dimensions of human cusps, in particular the cusp height. METHODS The cusp height was measured intraoperatively in 621 patients during aortic valve repair procedures. A tricuspid anatomy was present in 329 patients and bicuspid in 286 patients. In addition, patient...

متن کامل

Repair of aortic valve prolapse: experience with 44 patients.

OBJECTIVES In regurgitant tricuspid aortic valves, cusp prolapse may be isolated or associated with dilatation of the proximal aorta. Newly appearing cusp prolapse can also appear after an aortic valve sparing operation (AVSO) and be responsible for residual aortic regurgitation. In this report, we describe our experience in repairing prolapsing aortic cusps in 44 patients with aortic regurgita...

متن کامل

Aortic valve repair with ascending aortic aneurysms: associated lesions and adjunctive techniques.

OBJECTIVE Patients with supracoronary ascending aortic aneurysms can have aortic insufficiency (AI) due to dilatation of the sinotubular junction and/or associated cusp pathology. The incidence and types of cusp lesions as well as the effect of AI severity and cusp repair techniques on outcome in this patient population is not well defined. METHODS Since 1996, 55 patients (mean age: 65 ± 13 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2012