A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation.

نویسندگان

  • M Mirowski
  • M M Mower
  • A Langer
  • M S Heilman
  • J Schreibman
چکیده

Ventricular defibrillation was acheived in active conscious dogs with a chronically implanted automatic system composed of a defibrillator and an alternating current fibrillator. The hermetically sealed defibrillator is encased in titanium, weighs 250 g and has a volume of 145 ml. The sensor continuously monitors ventricular electircal activity and recognizes fibrillation by the absence of isoelectric potential segments. Fibrillation is induced by placing a magnet over the implanted fibrillator. The resulting syncope closely resembles the clinical entity of sudden death, while the defibrillator automatically restores normal rhythm with a truncated exponential pulse of 30 J, 15 seconds after the onset of the arrhythmia. The operational status of the defibrillator can be tested in vitro and noninvasively in vivo with an external analyzer. This experimental model allows for the first time a long-term study of the automatic implantable defibrillator approach to prevent sudden death from ventricular fibrillation under a variety of physiopathologic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of sudden change in cycle length on human atrial, atrioventricular nodal and ventricular refractory periods.

prevention of sudden coronary death. Arch Intern Med 126: 158, 1970 2. Mirowski M, Mower MM, Staewen WS, Denniston RH, Tabatznik B, Mendeloff AI: Ventricular defibrillation through a single intravascular catheter electrode system. (abstr) Clin Res 19: 328, 1971 3. Schuder JC, Stoeckle H, Gold JH, West JA, Keskar PY: Experimental ventricular defibrillation with an automatic and completely implan...

متن کامل

Autonomic mechanisms in ventricular fibrillation induced by myocardial ischemia during exercise in dogs with healed myocardial infarction. An experimental preparation for sudden cardiac death.

The relationship between activity of the autonomic nervous system, myocardial ischemia, and malignant arrhythmias has been investigated in a new experimental preparation for sudden death. Fifty-seven dogs were chronically instrumented and studied under control conditions (n = 15) and 1 month after production of an anterior myocardial infarction (n = 42). The protocol consisted in occluding the ...

متن کامل

Left stellectomy in the prevention of ventricular fibrillation caused by acute myocardial ischemia in conscious dogs with anterior myocardial infarction.

The potential of left stellectomy in reducing the incidence of ventricular fibrillation associated with acute myocardial ischemia was investigated in a new animal model for sudden death. Thirty-two dogs had an anterior myocardial infarction produced by ligation of the left descending coronary artery. One week later they were randomly allocated to a control or to an experimental group that under...

متن کامل

Automatic External Defibrillators: the Potential for Widespread Prevention of Sudden Cardiac Death in the Community

The vast majority of witnessed sudden cardiac death is due to the unpredictable occurrence of ventricular fibrillation, which is almost uniformly reversed by the immediate application of defibrillation. Thus, there is dire need for development of the appropriate conditions for early defibrillation in places where the likelihood of an unexpected sudden death event is deemed probable. In this set...

متن کامل

Lead systems for internal ventricular fibrillation.

We examined the feasibility of using a standby automatic implantable defibrillator and established thresholds for internal defibrillation. The implantable defibrillator senses ventricular fibrillation and delivers an electrical impulse for defibrillation. Two lead systems for the device have been investigated. System I consists of two 12-cm2 silicone-covered titanium mesh patches attached to th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 1978