Effect of eye testing order on automated perimetry results using the Swedish Interactive Threshold Algorithm standard 24-2.
نویسندگان
چکیده
OBJECTIVE To evaluate whether the order of eye testing affects the mean deviation (MD) or the test reliability of visual field testing using the Swedish Interactive Threshold Algorithm (SITA) standard 24-2. METHODS Consecutive patients with manifest or suspect glaucoma with 2 prior sets of SITA standard 24-2 test results performed on the right eye first were enrolled. A subsequent test was performed on the left eye first. For each eye, the MD and the test reliability indexes (> or = 20%) were compared among the 3 successive examinations. RESULTS Forty-seven patients (29 women and 18 men; mean +/- SD age, 70.6 +/- 11.9 years) were enrolled. The MD +/- SD was -5.83 +/- 5.43 dB OD and -5.46 +/- 4.86 dB OS. There was no statistically significant difference in the MD or the test reliability among the 3 test results for either eye. Fixation loss was responsible for the unreliable fields in almost all cases. CONCLUSIONS Among this cohort of patients experienced with automated perimetry in a glaucoma subspecialty practice, changing the order of eye testing using the SITA standard 24-2 did not have a significant effect on the MD or the test reliability. Intereye fatigue may not be clinically significant with this algorithm. Fixation loss remains a problem with the use of this algorithm.
منابع مشابه
Detecting visual function abnormalities using the Swedish interactive threshold algorithm and matrix perimetry in eyes with glaucomatous appearance of the optic disc.
OBJECTIVE To compare the ability of 24-2 frequency-doubling perimetry (FDP-Matrix) with standard automated perimetry with the Swedish interactive threshold algorithm (SAP-SITA) in detection of visual function abnormalities in patients with glaucomatous-appearing optic discs (GAOD). METHODS This observational case-control study included 80 patients with GAOD and 54 control subjects diagnosed b...
متن کامل[Functional relationship between retinal sensitivity threshold values assessed by standard automated perimetry in glaucoma].
OBJECTIVE To study the correlation between the sensitivity threshold values of the different points assessed by the Humphrey visual field analyzer (24-2 Swedish interactive threshold algorithm [SITA] standard strategy) in glaucoma patients. SUBJECTS, MATERIAL AND METHODS Prospective cross-sectorial study. One-hundred and four eyes of 104 glaucoma patients, defined by the appearance of the opt...
متن کاملThe Effect of Limiting the Range of Perimetric Sensitivities on Pointwise Assessment of Visual Field Progression in Glaucoma
PURPOSE Automated perimetry does not produce reliable estimates of true psychophysical threshold in glaucomatous visual fields when the perimetric threshold falls below 15 to 19 dB. It may be possible to truncate testing at such locations and not use stimuli with very high contrast. However, this can only be recommended if it does not harm the ability to monitor change. This study examined the ...
متن کاملBetween-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.
PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...
متن کاملUse of a continuous probability scale to display visual field damage.
OBJECTIVE To derive and display the percentile score (1st-99th percentile) at each perimetric location of a standard automated perimetry test to determine whether this technique will uncover patterns of loss not visible in standard (StatPac) probability maps. METHODS We computed continuous scale probability plots of data collected from testing 305 visually healthy participants with standard a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 124 6 شماره
صفحات -
تاریخ انتشار 2006