[Objective Assessment of Postoperative Results of Intraocular Lenses].
نویسندگان
چکیده
PURPOSE To prospectively compare postoperative results of two premium intraocular lenses EnVISTA (Bausch and Lomb) and AcrySof IQ (Alcon), focussing on glistenings and posterior capsule opacification. The evaluation of glistenings was done using Image J software and posterior capsule opacifications were quantified with OSCA system. METHODS Twenty patients (7 men and 13 women) with bilateral cataract were included. EnVista intraocular lens (IOL) was implanted in one eye and AcrySof IQ IOL in the second eye of each patient. Objective evaluation methods were used for assessment. Glistenings was quantified with ImageJ software and PCO using the Open-Access Systematic Capsule Assessment (OSCA) system (Devised by Aslam TM, Edinburgh, United Kingdom). Complete ophthtalmological evaluation including evaluation after pupil dilatation was done and digital images of intraocular lenses were obtained. The results of 2-, 4-, 6- and 12-month follow-up were compared. RESULTS Twenty patients were analyzed 2 months, 16 patients 4 months, 14 patients 6 months and 13 patients 12 months after cataract surgery. There was only minimal difference in best corrected visual acuity between EnVista and AcrySof group. The glistenings in the EnVista IOLs was objectively lower than in the AcrySof IOLs during whole follow-up period. In contrast to PCO, in eyes with AcrySof IOL was lower PCO score. CONCLUSION Development of new materials and techniques of cataract surgery is the topic of ophthtalmologists worldwide. Reduction of glistenings and PCO is one of the main aims, objective measurements is important part of assessment of postoperative results after cataract surgery. KEY WORDS glistenings, posterior capsule opacification, EnVista, AcrySof IQ, Image J software, OSCA system.
منابع مشابه
Phacotrabeculectomy and Implantation of Intraocular Lenses with Releasable Sutures and Antimetabolite Agents: Efficacy and Safety
Abstract Background: The aim of this study was to evaluate the efficacy and safety of phacoemulsification and the implantation of intraocular lenses (IOL) combined with trabeculectomy supplemented by releasable sutures and antimetabolite agents. Methods:Phacotrabeculectomy was performed in 36 eyes of 30 patients who hadmedically uncontrolle...
متن کاملICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison.
PURPOSE To compare the objective and subjective outcome of implantable collamer lenses (ICLs; Staar Surgical, Monrovia, CA) versus Veriflex lenses (AMO, Santa Ana, CA) for the correction of moderately high myopia. METHODS A prospective randomized comparative eye study was performed on 24 patients with bilateral myopia that ranged from -6 to -14.5 diopters (D). One eye was implanted with an IC...
متن کاملThe Predictability of Preoperative Pilocarpine-Induced Lens Shift on the Outcomes of Accommodating Intraocular Lenses Implanted in Senile Cataract Patients
Purpose. To evaluate the predictability of lens shift induced by pilocarpine (LSPilo) on the outcomes of accommodating intraocular lens (Acc-IOL) implantation. Methods. Twenty-four eyes of 24 senile cataract patients who underwent phacoemulsification and Acc-IOL implantation were enrolled. LSPilo was evaluated with anterior segment optical coherence tomography (AS-OCT). At 3 months postoperativ...
متن کاملBilateral implantation of asymmetrical diffractive multifocal intraocular lenses.
OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...
متن کاملRotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study
BACKGROUND To evaluate the rotational stability of the three types of AcrySof SA60TT toric intraocular lenses (Alcon, Switzerland) in cataract surgery after the first postoperative week. METHODS A retrospective study of 44 eyes in 33 patients. All patients underwent similar uncomplicated phacoemulsification cataract surgery. Seven eyes with corneal astigmatism of less than 1.5 D were implante...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti
دوره 72 3 شماره
صفحات -
تاریخ انتشار 2017