[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].

نویسندگان

  • Daniel Hernandez-Vaquero
  • David Calvo
  • Jose M Garcia
  • Iñigo Lozano
  • Carlos Morales
  • Jose Luis Naya
  • Cesar Moris
  • Juan C Llosa
چکیده

INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent surgery for aortic valve replacement due to severe stenosis in our center from February 2004 to April 2009. Patient-prosthesis mismatch was considered to exist when the indexed effective orifice area was ≤ 0.85 cm²/m². The influence of patient-prosthesis mismatch on in-hospital mortality, medium-term survival, and New York Heart Association functional class was studied using an analysis adjusted for propensity score. RESULTS Of 149 patients studied, 61.7% had some degree of patient-prosthesis mismatch (mean follow-up was 32.71 ± 14.42 months). After adjusting for propensity score, there were no differences in in-hospital mortality (odds ratio=0.75; 95% confidence interval, 0.15-3.58; P=.72), medium-term survival (hazard ratio=1; 95% confidence interval, 0.36-2.78; P=.99) or functional class during follow-up (odds ratio=1.46; 95% confidence interval, 0.073-29.24; P=.8). CONCLUSIONS Although moderate patient-prosthesis mismatch is a very common finding in octogenarian patients who undergo aortic valve replacement, its influence on mortality and quality of life does not seem to be relevant. The biological profile of elderly patients with lower metabolic requirements and limited physical activity could justify the results obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-term impact of patient-prosthesis mismatch on young and middle-aged patients undergoing surgery due to severe aortic stenosis

Methods All patients younger than 70 years of age undergoing isolated aortic valve replacement from October 2005 to October 2011 were analyzed. Patient-prosthesis mismatch was defined as the indexed effective orifice area ≤ 0,85cm2/m2. We studied the impact of patient-prosthesis mismatch on mid-term overall mortality, cardiac events and New York Heart Association functional class using an analy...

متن کامل

Impact of patient-prosthesis mismatch on 30-day outcomes in young and middle-aged patients undergoing aortic valve replacement

BACKGROUND The impact of patient-prosthesis mismatch (PPM) on early outcomes in young and middle-aged patients undergoing conventional aortic valve replacement for severe aortic stenosis remains unknown. Our objective was to evaluate the incidence of some degree of PPM and its influence on early mortality and morbidity. METHODS We analyzed our single center experience in all patients <70 year...

متن کامل

Octogenarian with an untreated femoral neck fracture: upright position during the postoperative course after aortic valve replacement.

We describe a patient with a femoral neck fracture undergoing an aortic valve replacement. The study design was a case report. An 82-year-old female with an untreated right femoral neck fracture, and a severe aortic valve stenosis was admitted to a cardiac surgery department for surgical treatment of the valve disease. She underwent aortic valve replacement with a sutureless biological valve pr...

متن کامل

Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

OBJECTIVE We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderat...

متن کامل

Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.

OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 64 9  شماره 

صفحات  -

تاریخ انتشار 2011