Anatomical factors involved in difficult cardiac resynchronization therapy procedure: a non-invasive study using dual-source 64-multi-slice computed tomography.

نویسندگان

  • Antoine Da Costa
  • Alexie Gate-Martinet
  • Pierre Rouffiange
  • Alexis Cerisier
  • Abdallah Nadrouss
  • Laurence Bisch
  • Cécile Romeyer-Bouchard
  • Karl Isaaz
چکیده

AIMS In cardiac resynchronization therapy (CRT) procedure, left ventricular (LV) lead implantation is time consuming. In this clinical setting, no study has investigated the impact of right atrium anatomical parameters on both CRT implantation procedure duration and X-ray exposure. Additionally, only few studies have examined the coronary sinus (CS) using dual-source 64-multi-slice computed tomography (DS 64-MSCT), and its impact on CRT procedure parameters has not yet been investigated. The aim of this prospective study was to identify local anatomical predictive factors of difficult CRT implantation procedure using DS 64-MSCT. METHODS AND RESULTS Between January and July 2010, 50 consecutive patients underwent primo CRT implantation. The patient population had a mean age of 70 ± 10 years, and was 34% female, with New York Heart Association Class 3.2 ± 0.3 heart failure, left ventricle ejection fraction 30 ± 4%, and QRS width 157 ± 30 ms. Cardiac resynchronization therapy implantation was attempted in 50 patients, and first LV lead implantation was obtained in 49 of 50 patients (98% primary success). One implantation failed (2%) due to unsuccessful LV lead implant. Procedure parameters were as follows: LV threshold, 1.4 ± 0.8 V; LV wave amplitude, 17 ± 8 mV; LV impedance, 830 ± 240 Ω; median procedure time (skin to skin), 51 min (38 min); median fluoroscopy procedure time, 11.9 min (22 min); and median LV fluoroscopic time, 10.3 min (22 min). In 10 patients (20%), procedures were difficult requiring an implantation lasting ≥ 85 min. The only predictive factor for difficult CRT implantation was the insertion level of the CS ostium (CSO), evaluated by the distance between the CSO and the bottom floor of the right atrium (14.8 ± 4 vs. 9.5 ± 4; P= 0.01). Neither the right atrium dilation nor right ventricular dysfunction was associated with difficult CRT implantation procedures. CONCLUSIONS Today, despite improvements in the materials used, problems still remain in the CRT procedure. In this clinical setting, the only predictive factor for very long CRT procedures is the CSO-level insertion (located high). This anatomical anomaly identified by DS 64-MSCT prior to surgery is responsible for 20% of difficult CRT device implantation procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A user-friendly method of cardiac venous system visualization in 64-slice computed tomography.

BACKGROUND Previsualization of the cardiac venous system is very important for some techniques, for example, cardiac resynchronization therapy (CRT). The aim of this study was to propose a new, user-friendly method of cardiac venous system visualization in 64-slice computed tomography (CT). METHODS In 112 patients (66 M) aged 58 +/- 11 standard deviation, a 64-slice CT with a retrospective el...

متن کامل

Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography.

OBJECTIVES This study was designed to evaluate the value of 64-slice computed tomography (CT) to visualize the cardiac veins and evaluate the relation between variations in venous anatomy and history of infarction. BACKGROUND Cardiac resynchronization therapy (CRT) is an attractive treatment for selected heart failure patients. Knowledge of venous anatomy may help in identifying candidates fo...

متن کامل

Quality of visualization of coronary venous system in 64-slice computed tomography.

BACKGROUND Multi-slice computed tomography (MSCT) can be used to visualize the anatomy of the coronary venous system (CVS). A pre-procedural evaluation of target veins is a very important element of cardiac resynchronization. Thus, the quality of visualization of the CVS is of great importance. The aim of this study was to analyze the quality of visualization of CVS in MSCT. METHODS In 220 su...

متن کامل

The challenge to detect heart transplant rejection and transplant vasculopathy non-invasively - a pilot study

BACKGROUND Cardiac allograft rejection and vasculopathy are the main factors limiting long-term survival after heart transplantation.In this pilot study we investigated whether non-invasive methods are beneficial to detect cardiac allograft rejection (Grade 03 R) and cardiac allograft vasculopathy. Thus we compared multi-slice computed tomography and magnetic resonance imaging with invasive met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2012