Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures
نویسندگان
چکیده
BACKGROUND The dynamic compression screw is a plate and screws implant used to treat fractures of the distal femur. The Biomet Matthews Nail is a new retrograde intramedullary nail designed as an alternative surgical option to treat these fractures. The objective of this study was to assess the comparative endurance of both devices. METHOD The dynamic compression screw (DCS) and Biomet Matthews Nail (BMN) were implanted into composite femurs, which were subsequently cyclically loaded using a materials testing machine. Simulated fractures were applied to each femur prior to the application of load. Either a Y type fracture or a transverse osteotomy was prepared on each composite femur using a jig to enable consistent positioning of cuts. RESULTS The Biomet Matthews Nail demonstrated a greater endurance limit load over the dynamic compression screw in both fracture configurations. CONCLUSION The distal locking screws pass through the Biomet Matthews Nail in a unique "cruciate" orientation. This allows for greater purchase in the bone of the femoral condyle and potentially improves the stability of the fracture fixation. As these fractures are usually in weak osteoporotic bone, the Biomet Matthews Nail represents a favourable surgical option in these patients.
منابع مشابه
Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)
Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...
متن کاملBiomechanical Comparison for Unstable Femoral-supracondylar Fractures Treated with Retrograde, Traditional Femoral or Tibial Locked Nails
Retrograde locked intramedullary nailing has gradually been widely used to treat femoral supracondylar fractures. Because a standard femoral supracondylar nail has unique disadvantages: high price and potentially inducing a femoral shaft stress fracture, it is often replaced by a traditional femoral or tibial locked nail. A biomechanical comparison was therefore made between both traditional lo...
متن کاملRetrograde nailing of a femoral supracondyle.
Because standard femoral supracondylar nails have certain disadvantages, they are often replaced by traditional femoral or tibial locked nails. The purpose of this study was to make a biomechanical comparison between both types of traditional locked nails to determine which technique was more suitable for treating unstable femoral supracondylar fractures. Fourteen left Sawbones femurs (Pacific ...
متن کاملIs Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?
In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...
متن کاملSupracondylar Fracture Femur; Dynamic Condylar Screw Fixation Experience at Liaquat University Hospital Jamshoro
.. Objectives: Our experience by dynamic condylar screw in the treatment of supracondylar femur fracture, which is quite a long time, has stayed challengeable issue in orthopedic surgery, at LUH. Study Design: An observational cross sectional study. Setting: Orthopedic Surgery Department, Liaquat University. Methodology: Cases along both sexes with additional articular fractures, conceded insid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 7 شماره
صفحات -
تاریخ انتشار 2008