E. Ozarslan, B. C. Vemuri, S. J. Blackband National Institutes of Health, Bethesda, MD, United States, University of Florida, Gainesville, FL, United States INTRODUCTION The diffusion orientation transform (DOT) enables the estimation of water displacement probability profiles from high angular resolution diffusion-weighted MRI data, making it possible to map the structural connectivity information even in regions with complex microstructure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT).

This article describes an accurate and fast method for fiber orientation mapping using multidirectional diffusion-weighted magnetic resonance (MR) data. This novel approach utilizes the Fourier transform relationship between the water displacement probabilities and diffusion-attenuated MR signal expressed in spherical coordinates. The radial part of the Fourier integral is evaluated analyticall...

متن کامل

Application of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation

Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...

متن کامل

Diffusion Propagator Imaging (DPI): an alternative to Diffusion Spectrum Imaging (DSI)

INTRODUCTION: The quest of diffusion-weighted (DW) imaging is to non-invasively obtain information about the average diffusion of water molecules in biological tissue. Many recent high angular resolution diffusion imaging (HARDI) [1, and references therein] techniques are proposed to infer the diffusion or fiber orientation distribution function (ODF), but this ODF only captures the angular str...

متن کامل

Model-Free and Analytical EAP Reconstruction via Spherical Polar Fourier Diffusion MRI

How to estimate the diffusion Ensemble Average Propagator (EAP) from the DWI signals in q-space is an open problem in diffusion MRI field. Many methods were proposed to estimate the Orientation Distribution Function (ODF) that is used to describe the fiber direction. However, ODF is just one of the features of the EAP. Compared with ODF, EAP has the full information about the diffusion process ...

متن کامل

Application of Wavelet Transform as a Signal Processing Method for Defect Detection using Lamb Waves: Experimental Verification

A Lamb wave-based crack detection method for aluminum plates health monitoring is developed in this paper. Piezoelectric disks are employed to actuate and capture the Lamb wave signals. The position of crack is assumed to be aligned with the sensor and actuator.  Extraction of high quality experimental results of lamb wave propagation in a plate-like structure is considerably complicated due to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005