Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders--a single centre experience.
نویسندگان
چکیده
BACKGROUND Perimembranous ventricular septal defect (VSD) is the most common congenital heart defect. Percutaneous transcatheter closure of VSD is one of the greatest challenges in interventional cardiology. AIM Presentation of our experience in transcatheter closure of perimembranous VSD. METHODS Eighteen patients were treated. Nine patients (group I) had VSD closed with implant Amplatzer Perimembranous VSD Occluder (PMVSDO) whereas the other nine had VSD closed with Muscular VSD Occluder (MVSDO). In the second group the presence of at least 4 mm rim from aortic valve was mandatory to undergo the procedure. Average patients age was 17.1 (3.2-40) years, defect diameter--4.7 (4-8) mm and Qp/Qs ratio--1.84 (1.5-4.6). Perimembranous interventricular septum aneurysm was noted in 5 cases. Only patients who had hemodynamically important defect (Qp/Qs ratio >1.5) were selected for interventional VSD closure. Patients with subarterial VSDs, pulmonary hypertension or/and aortic regurgitation were excluded. Ventricular septal defect closure was performed with standard techniques. RESULTS Procedures were completed successfully in 16 of 18 patients. There was no early or late implant embolisation. After the procedure in every case complete closure or important reduction of the shunt was observed. In the group I there was a trend towards more frequent occurrence of rhythm disturbances (p=0,08), including two cases with severe arrhythmias occurring during VSD closure requiring abandoning of procedure. In other 2 cases (patients age 12 and 14 years) in the second week after PMVSDO placement complete atrio-ventricular block occurred. In one patient sinus rhythm was restored after steroid treatment whereas another patient required pacemaker implantation. In group II mild nonprogressive tricuspid regurgitation was noted in 3 patients. CONCLUSIONS Percutaneous perimembranous VSD closure is an interesting alternative to surgical treatment. In selected cases closure of the defect with muscular VSD implant is effective and safe.
منابع مشابه
Safety and efficacy of Amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up
Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in sev...
متن کاملTranscatheter closure of ventricular septal defects using the Amplatzer Duct Occluder II device: a single-center experience
INTRODUCTION Off-label use of different devices has been described for percutaneous closure of ventricular septal defects (VSD) because of the unacceptable rate of post-procedure heart block associated with special VSD devices. AIM To describe the early single-center clinical experience with closure of a VSD using the Amplatzer Duct Occluder II (ADO II) device in children. MATERIAL AND METH...
متن کاملChanges in Serum Natriuretic Peptide Levels after Percutaneous Closure of Small to Moderate Ventricular Septal Defects
Background. B-type natriuretic peptide has been shown to be a very sensitive and specific marker of heart failure. In this study, we aimed to investigate the effect of percutaneous closure of ventricular septal defects with Amplatzer septal occluders on brain natriuretic peptide levels. Methods. Between 2008 and 2011, 23 patients underwent successfully percutaneous ventricular septal defect clo...
متن کاملPercutaneous closure of perimembranous ventricular septal defects associated with septal aneurysm in adults.
OBJECTIVE Percutaneous closure of perimembranous ventricular septal defects (pmVSD) has become an accepted alternative to surgical closure in selected cases. However, closure of pmVSDs associated with septal aneurysm is more challenging. We report our experience of device closure of pmVSDs associated with septal aneurysm. METHODS Between 2008 and 2012, percutaneous closure of pmVSD associated...
متن کاملSurgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kardiologia polska
دوره 66 9 شماره
صفحات -
تاریخ انتشار 2008