Cancellous bone osseointegration is enhanced by in vivo loading.
نویسندگان
چکیده
Biophysical stimuli may be an effective therapy to counteract age-related changes in bone structure that affect the primary stability of implants used in joint replacement or fracture fixation. The influence of controlled mechanical loading on osseointegration was investigated using an in vivo device implanted in the distal lateral femur of 12 male rabbits. Compressive loads (1 MPa, 1 Hz, 50 cycles/day, 4 weeks) were applied to a porous titanium foam implant and the underlying cancellous bone. The contralateral limbs served as nonloaded controls. Backscattered electron imaging indicated that the amount of bone ingrowth was significantly greater in the loaded limb than in the nonloaded control limb, whereas the amount of underlying cancellous periprosthetic bone was similar. No significant difference in the mineral apposition rate of the bone ingrowth or periprosthetic bone was measured in the loaded compared to the control limb. Histological analysis demonstrated newly formed woven bone in direct apposition to the implant coating, with a lack of fibrous tissue at the implant-periprosthetic bone interface in both loaded and nonloaded implants. The lack of fibrous tissue demonstrates that mechanical stimulation using this model significantly enhanced cancellous bone ingrowth without the detrimental effects of micromotion. These results suggest that biophysical therapy should be further investigated to augment current treatments to enhance long-term fixation of orthopedic devices. Additionally, this novel in vivo loading model can be used to further investigate the influence of biophysical stimulation on other tissue engineering approaches requiring bone ingrowth into both metallic and nonmetallic cell-seeded scaffolds.
منابع مشابه
Evaluation of multiple implant-bone parameters on stress characteristics in the mandible under traumatic loading conditions.
PURPOSE The inter-relationships between various implant and bone parameters were evaluated for their influence on the von Mises stress distribution within the mandible using the finite element procedure. The maximum compressive stresses in cancellous and cortical bone were compared to the published stress-strain data to determine bone fracturing status when the maximum (traumatic) loading is ap...
متن کاملIn Vivo Osseointegration Performance of Titanium Dioxide Coating Modified Polyetheretherketone Using Arc Ion Plating for Spinal Implant Application
Polyetheretherketone (PEEK), which has biomechanical performance similar to that of human cancellous bone, is used widely as a spinal implant material. However, its bioinertness and hydrophobic surface properties result in poor osseointegration. This study applies a novel modification method, arc ion plating (AIP), that produces a highly osteoblast compatible titanium dioxide (TiO2) coatings on...
متن کاملChitosan/siCkip-1 biofunctionalized titanium implant for improved osseointegration in the osteoporotic condition
Biofunctionalization with siRNA targeting the key negative modulators of bone turnover involved in the molecular mechanism of osteoporosis, such as casein kinase-2 interacting protein-1 (Ckip-1), may lead to enhanced Ti osseointegration in the osteoporotic condition. In this study, even siRNA loading was accomplished by the thermal alkali (TA) treatment to make the Ti ultrahydrophilic and negat...
متن کاملCancellous bone adaptation to tibial compression is not sex dependent in growing mice.
Mechanical loading can be used to increase bone mass and thus attenuate pathological bone loss. Because the skeleton's adaptive response to loading is most robust before adulthood, elucidating sex-specific responses during growth may help maximize peak bone mass. This study investigated the effect of sex on the response to controlled, in vivo mechanical loading in growing mice. Ten-week-old mal...
متن کاملExternal Mechanical Microstimuli Modulate the Osseointegration of Titanium Implants in Rat Tibiae
PURPOSE To assess the effect of external mechanical microstimuli of controlled magnitude on the microarchitecture of the peri-implant bone beds in rat tibiae. MATERIALS AND METHODS Tibiae of forty rats were fitted with two transcutaneous titanium cylinders. After healing, the implants were loaded to 1 to 3 N, five days/week for four weeks. These force levels translated into intraosseous strai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Tissue engineering. Part C, Methods
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2010