Determination of tertiary amines based on pH junctions and field amplification in capillary electrophoresis with electrochemiluminescence detection.
نویسندگان
چکیده
A stacking approach based on pH junction and field amplification has been developed for determining amines by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. A two-electrode configuration was employed with an indium/tin oxide-coated glass as a working electrode and a platinum wire as a pseudoreference electrode. The ECL system also contains a flow cell (poly(dimethylsiloxane)-aluminum oxide) that was made from a mixture of Sylgard 184 silicone elastomer, a curing agent, and aluminum oxide. In order to improve the sensitivity of the present CE-ECL system using tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3) (2+)), a stacking approach based on pH junctions and field amplification has been tested for the analysis of triethylamine (TEA), tripropylamine (TPA), and tributylamine (TBA). Once amines (cations) prepared in citric acid solution (pH < 4.0) migrate towards the background electrolyte (15 mM sodium borate at pH 8.0), they slow down and are stacked at the boundary as a result of deprotonation and decreases in the electric field. By applying hydrodynamic injection of the sample for 60 s, this method provides the concentration limits of detection (signal-to-noise ratio = 3) of 24, 20, and 32 nM for TEA, TPA, and TBA, respectively. The results indicate that the stacking CE-ECL system is better than CE-ECL systems using a two-electrode configuration and comparable to those using a three-electrode configuration. The potential applicability of the new and low-cost CE-ECL system has been demonstrated by the determination of 1.0 microM lidocaine, a local anesthetic drug, in urine without any tedious sample preparation.
منابع مشابه
Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis
Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...
متن کاملDetermination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis
Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملDetermination of Tramadol in Human Serum by Capillary Electrophoresis with the End-Column Electrochemiluminescence Detection
A capillary electrophoresis (CE) coupled with end-column electrochemiluminescence (ECL) detection method for the analysis of tramadol (TMD) has been investigated. ECL detection was working electrode biased at 1.2 V in a 20 mmol·L sodium phosphate buffer (pH = 8.0) containing 5 mmol·L Ru 3 bpy (where bpy = 2,2’-bipyridyl). Linear correlation (r ≥ 0.997) between ECL intensity and drug conce...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 26 15 شماره
صفحات -
تاریخ انتشار 2005