Quantitation of In-Vivo Metabolic Kinetics of Pyruvate using Hyperpolarized 13C MRSI

نویسندگان

  • T. Xu
  • D. Mayer
  • M. Gu
  • Y-F. Yen
  • S. Josan
  • E. Johansson
  • J. Tropp
  • R. Hurd
  • D. Spielman
چکیده

T. Xu, D. Mayer, M. Gu, Y-F. Yen, S. Josan, E. Johansson, J. Tropp, R. Hurd, and D. Spielman Department of Electrical Engineering, Stanford University, Stanford, CA, United States, Department of Radiology, Stanford University, Stanford, CA, United States, Neuroscience Program, SRI International, Menlo Park, CA, United States, Global Applied Sciences Laboratory, GE Healthcare, Menlo Park, CA, United States, Medical Diagnostics R&D, GE Healthcare, Oslo, Norway, Global Applied Sciences Laboratory, GE Healthcare, Fremont, CA, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperpolarized 13C MR metabolic imaging can detect neuroinflammation in vivo in a multiple sclerosis murine model.

Proinflammatory mononuclear phagocytes (MPs) play a crucial role in the progression of multiple sclerosis (MS) and other neurodegenerative diseases. Despite advances in neuroimaging, there are currently limited available methods enabling noninvasive detection of MPs in vivo. Interestingly, upon activation and subsequent differentiation toward a proinflammatory phenotype MPs undergo metabolic re...

متن کامل

Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

BACKGROUND Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and ...

متن کامل

Investigation of tumor hyperpolarized [1-13C]-pyruvate dynamics using time-resolved multiband RF excitation echo-planar MRSI.

Hyperpolarized [1-(13)C]-pyruvate is an exciting new agent for the in vivo study of cellular metabolism and a potential cancer biomarker. The nature of the hyperpolarized signal poses unique challenges because of its short duration and the loss of magnetization with every excitation. In this study, we applied a novel and efficient time-resolved MR spectroscopic imaging (MRSI) method to investig...

متن کامل

Assessing ischemic myocardial metabolism in vivo with hyperpolarized 13C: relating the metabolic perturbation to the area at risk

Background The high metabolic activity of the heart makes it particularly suited to the use of hyperpolarized (HP) 13C methods to non-invasively detect and characterize metabolic changes that occur during ischemia/reperfusion (I/R). Energy metabolism in ischemic rat hearts has been previously interrogated with HP 13C-labelled pyruvate ex vivo, and its hyperpolarized metabolites have been imaged...

متن کامل

Kinetic Modeling of Hyperpolaized [1-13C]Pyruvate Metabolism in Blood

INTRODUCTION Dynamic Nuclear Polarization (DNP) of metabolically active 13C-labelled substances has been reported as a method of generating MR images of in vivo cellular metabolism [1] and hence has the potential to detect aggressive cancers that exhibit heightened metabolism [2]. By injecting active, hyperpolarized 13C metabolites such as pyruvate, it is possible to visualize their transformat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009