Determination of Lactate with Liquid Chromatography/Electrochemistry Coupled with a Lactate Oxidase IMER

نویسنده

  • Liu Yang
چکیده

published for the determination of lactate using liquid chromatography. One method (1) involves reverse-phase separation with a phosphate buffer at pH 3 as the mobile phase. Following the separation, the lactate is converted to hydrogen peroxide by a lactate oxidase IMER and then detected amperometrically. The optimal pH for the enzyme lactate oxidase is around 7, and at pH 3 the enzyme is basically not functioning. Therefore, for this system, a second pump and an online mixer have to be used to increase the pH of the mobile phase after the separation column to keep the enzyme in the IMER active. This makes the system rather complicated. Another method (2) also involving reverse-phase separation with low pH phosphate buffer uses UV detection instead of the electrochemical detection coupled with a lactate oxidase IMER. Lactate does not absorb in the usual UV-VIS region, and the direct detection of lactate has to be conducted in the low wavelength UV region. This makes serious background interferences likely. There is also a reversephase separation using a mixture of phosphate and acetonitrile as mobile phase. For this separation, there are two detection methods: UV-VIS spectrophotometry (3) and fluorimetry (4). For both detection methods, the lactate has to be derivatized and therefore the methods are not convenient. Ion chromatography has also been used for the separation of lactate. The two published methods use conductimetric (5) and acoustic wave (6) detection. The conductimetric method requires several ion-exchange steps to reduce the background, resulting in a very complicated system. Besides, the chromatogram usually involves many anionic peaks that make data analysis difficult. The acoustic wave method, on the other hand, is limited by its lack of commercial availability and difficult data interpretation. In this paper we describe the development of a simple and practical LCEC method for the determination of lactate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

hide.chp:Corel VENTURA

acetylcholine (ACh) in prefrontal cortex (mPFC) plays an important role in some domains of cognitive function such as attention (1,2), and sensory gating (3). Therefore, measurement of ACh in a living animal is important for the development of novel drugs, as well as investigation of brain function. Microdialysis has proven to be a useful sampling technique in the brain of awake freelymoving an...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Amperometric biosensor for lactate analysis in wine and must during fermentation

A lactate oxidase-based amperometric biosensor is designed for lactate determination. Two methods of lactate oxidase immobilization on the surface of commercial SensLab platinum printing electrodes are compared. The sensor with lactate oxidase immobilized by physical adsorption in Resydrol polymer is shown to have both narrower dynamic range (0.004– 0.5 mМ lactate) and higher sensitivity (320 n...

متن کامل

Determination of Astaxanthin in Trout by High Performance Liquid Chromatography Coupled with Visible Detection

Background: Astaxanthin is widely and naturally distributed in marine animals including, crustaceans, such as shrimp, crabs, and fish, such as salmon and trout. Methods: A total of 20 trout samples were collected from local market and were analyzed for astaxanthin via HPLC-UV. Analyte extraction was done by water, methanol, dichloromethane, and acetonitrile 4.5:85:5:45.5, v/v/v/v. Results: Desp...

متن کامل

Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method

Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000