Methodological analysis of diagnostic dobutamine stress echocardiography studies.

نویسندگان

  • Boudewijn J Krenning
  • Marcel L Geleijnse
  • Don Poldermans
  • Jos R T C Roelandt
چکیده

BACKGROUND Dobutamine stress echocardiography (DSE) is an accepted test for the diagnosis of coronary artery disease (CAD), despite its wide diagnostic accuracy. AIM Which factors cause test variability of DSE for the diagnosis of CAD. METHODS In a retrospective analysis of 46 studies in 5,353 patients, the potential causes of diagnostic variability were systematically analyzed, including patient selection, definition of CAD, chest pain characteristics, confounding factors for DSE (left ventricular hypertrophy, left bundle branch block, female gender), work-up bias (present when patient's chance to undergo coronary angiography is influenced by the result of DSE), review bias (present when DSE is interpreted in relation to CAG), DSE protocol and definition of a positive DSE. RESULTS Diagnostic variability was related to definition of a positive test, but not related to the definition of CAD or DSE protocol. However, only three of eight methodological standards for research design found general compliance. Differences in the selection of the study population (quality of echocardiographic window, angina pectoris), handling of confounding factors and analysis of disease in individual coronary arteries were observed. Lack of data on analysis of relevant chest pain syndromes and handling of nondiagnostic test results hampered further evaluation of these standards. CONCLUSION Methodological problems may explain the wide range in diagnostic variability of DSE. An improvement of clinical relevance of DSE testing is possible by stronger adherence to common and new methodological standards.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Artery Spasm During Dobutamine Stress Echocardiography: A Case Report

Dobutamine stress echocardiography (DSE) has been widely used as a diagnostic and prognostic modality in the management of stress. DSE is associated with limited complications and adverse effects on the health of patients. In this case report, we described a 42-year-old female patient with dobutamine-induced coronary artery spasm with history of exertional dyspnea, which had deteriorated recent...

متن کامل

Reliability and Safety of Dobutamine Stress Echocardiography for Detection of Myocardial Ischemia-Viability: Experience From 802 Consecutive Studies

S tress echocardiography (pharmaceutical or exercise) represents an important diagnostic method for the evaluation of coronary artery disease (myocardial ischemia and/or viability). The commonest protocol applied in stress echocardiography is carried out with intravenous administration of dobutamineatropine. Although some adverse reactions may appear during this procedure, many studies have pro...

متن کامل

Cardiac testing for coronary artery disease in potential kidney transplant recipients: a systematic review of test accuracy studies.

BACKGROUND Cardiovascular disease is the leading cause of death after kidney transplant. Screening for coronary artery disease is integral to pretransplant evaluation, although the relative performance of different tests is uncertain. STUDY DESIGN Systematic review of diagnostic test accuracy studies using hierarchical summary receiver operating characteristic analysis. SETTING & POPULATION...

متن کامل

A meta-analysis comparing the prognostic accuracy of six diagnostic tests for predicting perioperative cardiac risk in patients undergoing major vascular surgery.

OBJECTIVE To evaluate the discriminatory value and compare the predictive performance of six non-invasive tests used for perioperative cardiac risk stratification in patients undergoing major vascular surgery. DESIGN Meta-analysis of published reports. METHODS Eight studies on ambulatory electrocardiography, seven on exercise electrocardiography, eight on radionuclide ventriculography, 23 o...

متن کامل

Diagnostic and prognostic value of serial dobutamine stress echocardiography for noninvasive assessment of cardiac allograft vasculopathy: a comparison with coronary angiography and intravascular ultrasound.

BACKGROUND Routine methods for surveillance of cardiac allograft vasculopathy (CAV) are coronary angiography and intravascular ultrasound (IVUS). This study analyzed the diagnostic and prognostic value of dobutamine stress echocardiography (DSE) for noninvasive assessment of CAV. METHODS AND RESULTS In 109 heart transplant recipients, 333 DSEs were compared with 285 coronary angiograms and 19...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Echocardiography

دوره 21 8  شماره 

صفحات  -

تاریخ انتشار 2004