Volume-based characterization of postocclusion surge.
نویسندگان
چکیده
PURPOSE To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. SETTING Fundación Oftamológica Los Andes, Santiago, Chile. METHODS The distal end of a phacoemulsification handpiece was placed inside a compliant artificial anterior chamber. Digital recordings of chamber pressure, chamber volume, inflow, and outflow were performed during occlusion break of the phacoemulsification tip. The occlusion break profile of 2 different consoles was compared. RESULTS Occlusion break while using a rigid anterior chamber model produced a simultaneous increase of chamber inflow and outflow. In the rigid chamber model, pressure decreased sharply, reaching negative pressure values. Alternatively, with the collapsible chamber model, a delay was observed in the inflow that occurs to compensate the outflow surge. Also, the chamber pressure drop was smaller in magnitude, never undershooting below atmospheric pressure into negative values. Using 500 mm Hg as vacuum limit, the Infiniti System (Alcon) performed better that the Legacy (Alcon), showing an 18% reduction in peak volume variation. CONCLUSIONS The collapsible anterior chamber model provides a more realistic representation of the postocclusion surge events that occur in the real eye during cataract surgery. Peak volume fluctuation (mL), half volume recovery time(s), and volume fluctuation integral value (mL x s) are proposed as realistic indicators to characterize the postocclusion surge performance. These indicators show that the Infiniti System has a better postocclusion surge behavior than the Legacy System.
منابع مشابه
Condition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage current and maximum amplitude of fundamental harmonic of the capacitive leakage current were used as indicators for surge arrester condition mon...
متن کاملResearch of the Influential Factors on the Simulation of Storm Surge in the Bohai Sea
A hindcast of typical extratropical storm surge occurring in the Bohai Sea in Oct. 2003 is performed using a three-dimensional storm surge model system based on Finite-Volume Coastal Ocean Model (FVCOM). The surface winds are obtained from the WRF data set. Some preliminary sensitivity studies of the influential factors affecting the storm surge simulation in the Bohai Sea are studied with the ...
متن کاملEstimation of Increasing the Surge Capacity of Shaheed Rajaee Trauma Hospital in Shiraz
Background: The present study aimed to evaluate the surge capability of Shahid Rajaee Trauma Hospital in Shiraz in response to a mass causality incident. Methods: This descriptive study was conducted in Shahid Rajaee Hospital in Shiraz in 2017. The Delphi technique was used in this study. For this purpose, three checklists were used for the emergency department, operating room, and intensive c...
متن کاملSpontaneous cerebral hypothermia diminishes focal infarction in rat brain.
BACKGROUND AND PURPOSE Brain temperature during ischemia is known to strongly influence the extent of cellular injury. The objectives of the present study were to determine the effect of severe focal ischemia on brain temperature and to assess the influence of those changes on focal infarction. METHODS Severe focal ischemia was produced in rats using permanent occlusion of the distal middle c...
متن کاملDevelopment of a compression system dynamic simulation code for testing and designing of anti-surge control system
In recent years, several research activities have been conducted to develop knowledge in analysis, design and optimization of compressor anti-surge control system. Since the anti-surge control testing on a full-scale compressor is limited to possible consequences of failure, and also the experimental facility can be expensive to set up control strategies and logic, design process often involves...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 31 10 شماره
صفحات -
تاریخ انتشار 2005