Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

نویسندگان

  • M A R Siddiqui
  • A Azuara-Blanco
  • S Neville
چکیده

AIM To evaluate the effect of cataract surgery on frequency doubling technology (FDT) perimetry in patients with co-existing cataract and glaucoma. METHODS In this consecutive prospective cohort study 27 patients with open angle glaucoma scheduled for cataract extraction alone or combined with trabeculectomy were enrolled. All patients underwent FDT threshold C-20 visual fields within 3 months before and 3 months after surgery. Changes in mean deviation (MD) and pattern standard deviation (PSD) were evaluated. Additionally, changes in best corrected logMAR visual acuity (VA), intraocular pressure (IOP), and number of glaucoma medications were also studied. RESULTS 22 patients completed the study. VA improved after surgery, from 0.47 (SD 0.19) to 0.12 (0.17) (p<0.001). The visual indexes changed after cataract extraction: MD improved (from -10.9 (SD 4.6) dB to -7.0 (4.6) dB; p<0.001) while PSD worsened (from 7.1 (SD 3.5) dB to 8.5 (3.8) dB; p = 0.001). CONCLUSION In patients with co-existing cataract and glaucoma, examined with FDT, MD improved and PSD worsened after cataract surgery. Global indexes of FDT should be interpreted with caution in patients with glaucoma and cataracts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Agreement and correlation between the frequency doubling perimetry and the blue-yellow perimetry in glaucoma: no support for selective damage].

PURPOSE To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequ...

متن کامل

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...

متن کامل

Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.

AIM To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with ocular hypertension experienced with standard automated perimetry. METHODS Twenty-four patients with ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5+/-2 days. Learning effect was defined...

متن کامل

Variability components of standard automated perimetry and frequency-doubling technology perimetry.

PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 89 12  شماره 

صفحات  -

تاریخ انتشار 2005