Development of Multisite Microelectrodes for Neuroscience
نویسندگان
چکیده
Neural probes with a 32-site electrode array have been fabricated using an all-dry Si-etch based micromachining process. The fork-like probe shafts were formed by double-sided deep reactive ion etching (DRIE) of a silicon-on-insulator (SOI) substrate, with the buried SiO2 layer acting as an etch stop. The probe shafts typically had the dimensions of 4-15 mm (length), 25 μm (width), 20-30 μm (height) and a tip taper angle of 4°. An array of electrodes, each 100 μm, as well as Au conductor traces were formed by e-beam evaporation. Both Ir and Pt were used as electrode material and focused ion beam (FIB) studies, as well as electrical measurements, showed differences between these materials. Also a post process cleaning procedure was developed to remove process residues from the electrode surface. SEM studies showed well defined straight probe shafts with sharp probe tips. The function was verified in bench-top measurements and probes have been successfully used by neuroscientists in brain preparations. The next generation of probes, with 64-sites, have already been designed and are under way in the manufacturing process.
منابع مشابه
A Multichannel Data Acquisition and Analysis System based on off-the-shelf DSP Boards
The EU-funded project VSAMUEL aims to develop a versatile system for advanced neuronal recordings with multisite microelectrodes. Within this project we are developing a data acquisition system for high channel counts. The system will be able to acquire and process data on 128 channels at a sampling rate of at least 32 kHz. We are utilizing multiple DSP boards to perform that task. Other projec...
متن کاملInnovative Methodology Long-Term, Multisite, Parallel, In-Cell Recording and Stimulation by an Array of Extracellular Microelectrodes
Hai A, Shappir J, Spira ME. Long-term, multisite, parallel, in-cell recording and stimulation by an array of extracellular microelectrodes. J Neurophysiol 104: 559–568, 2010. First published April 28, 2010; doi:10.1152/jn.00265.2010. Here we report on the development of a novel neuroelectronic interface consisting of an array of noninvasive gold-mushroom-shaped microelectrodes (gM Es) that prac...
متن کاملLong-term, multisite, parallel, in-cell recording and stimulation by an array of extracellular microelectrodes.
Here we report on the development of a novel neuroelectronic interface consisting of an array of noninvasive gold-mushroom-shaped microelectrodes (gMmicroEs) that practically provide intracellular recordings and stimulation of many individual neurons, while the electrodes maintain an extracellular position. The development of this interface allows simultaneous, multisite, long-term recordings o...
متن کاملFlexible Split-Ring Electrode for Insect Flight Biasing Using Multisite Neural Stimulation Citation
We describe a flexible multisite microelectrode for insect flight biasing using neural stimulation. The electrode is made of two layers of polyimide (PI) with gold sandwiched in between in a split-ring geometry. The split-ring design in conjunction with the flexibility of the PI allows for a simple insertion process and provides good attachment between the electrode and ventral nerve cord of th...
متن کاملElectrical multisite stimulation of the isolated chicken retina
Visual prostheses such as subretinal implants are intended for electrical multisite excitation of the retinal network. To investigate relevant issues like spatial resolution and operational range, we have developed an in vitro method using microelectrode arrays to stimulate isolated retinae. Ganglion cell activity in the chicken retina evoked by distally applied spatial voltage patterns consist...
متن کامل