Direct Detection of Erythromycin-Resistant Bordetella pertussis in Clinical Specimens by PCR.
نویسندگان
چکیده
Resistance of Bordetella pertussis to erythromycin has been increasingly reported. We developed an allele-specific PCR method for rapid detection of erythromycin-resistant B. pertussis directly from nasopharyngeal (NP) swab samples submitted for diagnostic PCR. Based on the proven association of erythromycin resistance with the A2047G mutation in the 23S rRNA of B. pertussis, four primers, two of which were designed to be specific for either the wild-type or the mutant allele, were used in two different versions of the allele-specific PCR assay. The methods were verified with results obtained by PCR-based sequencing of 16 recent B. pertussis isolates and 100 NP swab samples submitted for diagnostic PCR. The detection limits of the two PCR assays ranged from 10 to 100 fg per reaction for both erythromycin-susceptible and -resistant B. pertussis. Two amplified fragments of each PCR, of 286 and 112 bp, respectively, were obtained from a mutant allele of the isolates and/or NP swab samples containing B. pertussis DNAs. For the wild-type allele, only a 286-bp fragment was visible when the allele-specific PCR assay 1 was performed. No amplification was found when a number of non-Bordetella bacterial pathogens and NP swab samples that did not contain the DNAs of B. pertussis were examined. This assay can serve as an alternative for PCR-based sequencing, especially for local laboratories in resource-poor countries.
منابع مشابه
Multiplex LightCycler PCR assay for detection and differentiation of Bordetella pertussis and Bordetella parapertussis in nasopharyngeal specimens.
A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS481 and IS1001 of B. pertussis and B. parapertussis, respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensit...
متن کاملIdentification of a mutation associated with erythromycin resistance in Bordetella pertussis: implications for surveillance of antimicrobial resistance.
Erythromycin treatment failures and in vitro resistance of Bordetella pertussis have been reported on several occasions in the past few years, but the mechanism of resistance has not been described. One potential mechanism, genetic modification of the erythromycin-binding site on the 23S rRNA of the 50S ribosomal subunit, has been observed in other bacteria. To explore this possibility, we ampl...
متن کاملComparison of PCR, culture, and direct fluorescent-antibody testing for detection of Bordetella pertussis.
We prospectively compared the performance of culture, direct fluorescent-antibody testing (DFA), and an in-house-developed PCR test targeting the repeated insertion sequence IS481 for the detection of Bordetella pertussis in nasopharyngeal swab specimens. We tested 319 consecutive paired specimens on which all three tests were performed. A total of 59 specimens were positive by one or more test...
متن کاملSurveillance and detection of erythromycin resistance in Bordetella pertussis isolates recovered from a pediatric population in the Intermountain West region of the United States.
Forty-seven Bordetella pertussis isolates recovered from January 1985 to June 1997 at Primary Children's Medical Center were tested for erythromycin resistance. Agar dilution MICs were determined on Regan-Lowe agar. Forty-six isolates were found to be erythromycin susceptible (all MICs were less than or equal to 0.12 microg/ml). One isolate was found to be erythromycin resistant (MIC, 32 microg...
متن کاملEvaluation and validation of a monoclonal immunofluorescent reagent for direct detection of Bordetella pertussis.
An outbreak of pertussis in Manitoba, Canada, provided an opportunity to evaluate the recently developed monoclonal antibody (MAb) BL-5 for the direct detection of Bordetella pertussis. The MAb recognizes a lipooligosaccharide epitope. A total of 1,507 consecutive nasopharyngeal swabs for culture and companion smears for direct fluorescent-antibody (DFA) detection were evaluated at Cadham Provi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 53 11 شماره
صفحات -
تاریخ انتشار 2015