Validation of the Microlife WatchBP O3 device for clinic, home, and ambulatory blood pressure measurement, according to the International Protocol.

نویسندگان

  • Fabio Ragazzo
  • Francesca Saladini
  • Paolo Palatini
چکیده

To determine the accuracy of the Microlife WatchBP O3 blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The WatchBP O3 is designed to provide clinic, ambulatory, and self blood pressure (BP) measurements. Device evaluation was performed in 33 participants with a mean +/- standard deviation age of 56.1+/-20.7 years (range 30-95 years). Their systolic BP (SBP) was 144.7+/-24.1 mmHg (range 90-180 mmHg), diastolic BP (DBP) was 86.8+/-18.3 mmHg (range 50-120 mmHg), and arm circumference was 28.1+/-2.9 cm (range 22.0-34.0 cm). Blood pressure measurements were performed in the sitting position. The WatchBP O3 passed all three phases of the European Society of Hypertension protocol for SBP and DBP. Mean blood pressure differences for the WatchBP O3 (device observer) were -1.7+/-6.9 mmHg for SBP and -1.1+/-4.3 mmHg for DBP. In conclusion, these results indicate that the Microlife WatchBP O3 monitor can be recommended for clinical use in the adult population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Questionable accuracy of home blood pressure measurements in the obese population – Validation of the Microlife WatchBP O3® and Omron RS6® devices according to the European Society of Hypertension-International Protocol

OBJECTIVE Two oscillometric devices, the Microlife WatchBP O3® and the Omron RS6®, designed for self-blood pressure measurement were evaluated according to the European Society of Hypertension (ESH)-International Protocol (IP) Revision 2010 in the obese population. METHODS The Microlife WatchBP O3 measures blood pressure (BP) at the brachial level and the Omron RS6 measures BP at the wrist le...

متن کامل

Microlife WatchBP studies

Ambulatory blood pressure monitoring (ABPM) is not widely used in clinical practice, because the measuring procedure is complex and the devices are expensive and need to be fitted by skilled medical technologists. The Microlife WatchBP O3 (Microlife AG, Widnau, Switzerland), which was developed for self blood pressure monitoring at home and adapted for ABPM, is highly affordable for an ABPM dev...

متن کامل

Validation of two devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the SEINEX SE-9400 and the Microlife BP 3AC1-1.

BACKGROUND Two electronic devices for self-measurement of blood pressure at the brachial artery -- the Seinex SE-9400 and the Microlife BP 3AC1-1 -- were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. DESIGN The international validation protocol is divided into two phases: the first phase is performed on 15 selected participa...

متن کامل

Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting

OBJECTIVE To evaluate the diagnostic performance of a UK National Institute for Health and Care Excellence-recommended automatic oscillometric blood pressure (BP) measurement device incorporated with an atrial fibrillation (AF) detection algorithm (Microlife WatchBP Home A) for real-world AF screening in a primary healthcare setting. SETTING Primary healthcare setting in Hong Kong. INTERVEN...

متن کامل

Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol.

BACKGROUND The market for devices for the self-measurement of blood pressure is growing, and as accuracy is of prime importance, there is increasing pressure for manufacturers to provide evidence of independent testing. Recent reviews have shown that only five automated upper arm devices for self-measurement of blood pressure have been recommended for use. We tested the Microlife BP 3BTO-A, a l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood pressure monitoring

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2010