Inertial Thigh Angle Sensing for a Semi-active Knee Prosthesis

نویسندگان

  • George Thomas
  • Daniel Simon
چکیده

We present an application of a microelectromechanical systems (MEMS)-based inertial measurement unit (IMU) to thigh angle estimation for the control of a semi-active knee prosthesis. By using inertial based measurement devices, we can move all of our sensors to one location inside the prosthetic leg. These sensors are challenging to use, however, because error in their measurements will accumulate over time. We show that by applying the Kalman filter to an IMU consisting of a dual-axis accelerometer and a singleaxis gyroscope, we can decrease the integral of squared error of our thigh angle estimates by 70%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis

In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...

متن کامل

A New Controlling Parameter in Design of Above Knee Prosthesis

In this paper after reviewing some previous studies, in order to optimize the above knee prosthesis, beside the inertial properties a new controlling parameter is informed. This controlling parameter makes the prosthesis able to act as a multi behavior system when the amputee is opposing to different environments. This active prosthesis with the new controlling parameter can simplify the contro...

متن کامل

Estimation of the Knee Flexion-Extension Angle During Dynamic Sport Motions Using Body-worn Inertial Sensors

Motion analysis has become an important tool for athletes to improve their performance. However, most motion analysis systems are expensive and can only be used in a laboratory environment. Ambulatory motion analysis systems using inertial sensors would allow more flexible use, e.g. in a real training environment or even during competitions. This paper presents the calculation of the flexion-ex...

متن کامل

Development of an Above Knee Prosthesis using MR Damper and Leg Simulator

Because conventional above-knee prostheses are passive type device with constant mechanical properties, knee joint motions are not similar to that of normal persons. On the other hand, active type prostheses can improve swing phase gait but these are expensive, heavy and consume large energy. So the semi-active type prostheses are presented. We propose to use the rotary MR damper. The torque di...

متن کامل

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis

The purpose of this study was two-fold: (1) demonstrate a technique that can be used to directly estimate the inertial properties of a below-knee prosthesis, and (2) contrast the effects of the proposed technique and that of using intact limb inertial properties on joint kinetic estimates during walking in unilateral, transtibial amputees. An oscillation and reaction board system was validated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012