Accuracy of Pedicle Screw Placement in Scoliosis Surgery: A Comparison between Conventional Computed Tomography-Based and O-Arm-Based Navigation Techniques
نویسندگان
چکیده
STUDY DESIGN Retrospective study. PURPOSE We compared the accuracy of O-arm-based navigation with computed tomography (CT)-based navigation in scoliotic surgery. OVERVIEW OF LITERATURE No previous reports comparing the results of O-arm-based navigation with conventional CT-based navigation in scoliotic surgery have been published. METHODS A total of 222 pedicle screws were implanted in 29 patients using CT-based navigation (group C) and 416 screws were implanted in 32 patients using O-arm-based navigation (group O). Postoperative CT was performed to assess the screw accuracy, using the established Neo classification (grade 0: no perforation, grade 1: perforation <2 mm, grade 2: perforation ≥2 and <4, and grade 3: perforation ≥4 mm). RESULTS In group C, 188 (84.7%) of the 222 pedicle screw placements were categorized as grade 0, 23 (10.4%) were grade 1, 11 (5.0%) were grade 2, and 0 were grade 3. In group O, 351 (84.4%) of the 416 pedicle screw placements were categorized as grade 0, 52 (12.5%) were grade 1, 13 (3.1%) were grade 2, and 0 were grade 3. Statistical analysis showed no significant difference in the prevalence of grade 2.3 perforations between groups C and O. The time to position one screw, including registration, was 10.9±3.2 minutes in group C, but was significantly decreased to 5.4±1.1 minutes in group O. CONCLUSIONS O-arm-based navigation facilitates pedicle screw insertion as accurately as conventional CT-based navigation. The use of O-arm-based navigation successfully reduced the time, demonstrating advantages in the safety and accuracy of pedicle screw placement for scoliotic surgery.
منابع مشابه
Accuracy and postoperative assessment of pedicle screw placement during scoliosis surgery with computer-assisted navigation: a meta-analysis.
BACKGROUND Accurate insertion of pedicle screws in scoliosis patients is a challenge for surgeons. Computer-assisted navigation techniques might help improve the accuracy of screw placement, thereby avoiding complications. Thus, the objective of this present work is to compare the accuracy and postoperative assessment of pedicle screw placement in scoliosis patients using a computer-assisted na...
متن کاملAccuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients
OBJECTIVE Two-dimensional fluoroscopy-based computerized navigation for the placement of pedicle screws offers the advantage of using stored patient-specific imaging data in providing real-time guidance during screw placement. The study aimed to describe the accuracy and reliability of a fluoroscopy-based navigation system for pedicle screw insertion. METHODS A total of 477 pedicle screws wer...
متن کاملCommentary: Utility of the O-Arm in spinal surgery
BACKGROUND More studies report the intraoperative benefits vs. risks of utilizing the O-Arm in performing pedicle screw insertion in spinal surgery. METHODS/RESULTS Several studies document the utility of CT-guided O-arm placement of pedicle/lateral mass screws. Singh et al. documented the efficacy of CT guided-O Arm placement of pedicle screws and lateral mass screws in the upper cervical sp...
متن کاملA medium invasiveness multi-level patient’s specific template for pedicle screw placement in the scoliosis surgery
BACKGROUND Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in or...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کامل