Voxel-Scale Digital Volume Correlation

نویسندگان

  • Hugo Leclerc
  • Jean-Noel Périé
  • Stéphane Roux
  • François Hild
  • Jean-Noël Périé
چکیده

Among various correlation techniques to find the displacement field of a volume imaged by X-Ray tomography at several deformation states, a new approach is proposed where the displacement is measured down to the voxel scale and determined from a mechanically regularized system using the equilibrium gap method, and an additional boundary regularization. It is shown that even if the underlying material behavior is not very well known, this approach leads to extremely small correlation residuals. An excellent stability of the estimated displacement field for noisy (reconstructed) volumes is also observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voxel-based morphometry and stereology provide convergent evidence of the importance of medial prefrontal cortex for fluid intelligence in healthy adults.

We investigated whether a relationship exists between frontal lobe volume and fluid intelligence as measured by both Cattell's Culture Fair test and the Wechsler Adult Intelligence Scale-Revised (WAIS-R) Performance scale, but not with crystallized intelligence as measured by the WAIS-R Verbal scale, in healthy adults, using two well-established image analysis techniques applied to high-resolut...

متن کامل

Digital Volume Correlation: What are the limits to the spatial resolution? Corrélation d'images volumiques : quelles limites à la résolution spatiale?

Most of the norms used in the eld of digital image (and volume) correlation to register two images (or volumes) lead to ill-posed problems. One of the frequent solutions is to enforce a restricted kinematics requiring a compromise between the richness of the solution (i.e., the spatial resolution) and the measurement uncertainty. An alternative route is to use a displacement norm that permits t...

متن کامل

Digital volume correlation: what are the limits to the spatial resolution?

Most of the norms used in the eld of digital image (and volume) correlation to register two images (or volumes) lead to ill-posed problems. One of the frequent solutions is to enforce a restricted kinematics requiring a compromise between the richness of the solution (i.e., the spatial resolution) and the measurement uncertainty. An alternative route is to use a displacement norm that permits t...

متن کامل

Three-dimensional digital topological characterization of cancellous bone architecture

Cancellous bone consists of a network of bony struts and plates that provide mechanical strength to much of the skeleton at minimum weight. It has been shown that loss in bone mass is accompanied by architectural changes that relate to both scale and topology of the network. In this paper, the concept of three-dimensional (3D) digital topology is presented for characterizing the local topology ...

متن کامل

Discrete volumetric digital image correlation for the investigation of granular type media at microscale: accuracy assessment

The recent development of efficient 3D imaging tools such as X-Rays computed microtomography combined with the extension to volumetric images of Digital Image Correlation (DIC) techniques provide new insights on the analysis of materials and structures. Among many other possible fields of application, geomaterials are good candidates for such investigations, owing to their relative transparency...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017