Comparison of susceptibility testing methods with mecA gene analysis for determining oxacillin (methicillin) resistance in clinical isolates of Staphylococcus aureus and coagulase-negative Staphylococcus spp.
نویسندگان
چکیده
Ninety-nine clinical staphylococcal isolates (58 coagulase-negative Staphylococcus spp. [CoNS] and 41 Staphylococcus aureus isolates) were evaluated for susceptibility to oxacillin. The following susceptibility testing methods, media, and incubation conditions were studied: agar dilution by using Mueller-Hinton (MH) medium (Difco) supplemented with either 0, 2, or 4% NaCl and incubation at 30 or 35 degrees C in ambient air for 24 or 48 h; disk diffusion by using commercially prepared MH medium (Difco) and MH II agar (BBL) and incubation at 35 degrees C in ambient air for 24 or 48 h; and agar screen (spot or swab inoculation) by using commercially prepared agar (Remel) or MH agar (Difco) prepared in-house, each containing 4% NaCl and 6 microg of oxacillin/ml (0.6-microg/ml oxacillin was also studied with MH agar prepared in-house for the agar swab method and CoNS isolates) and incubation at 35 degrees C in ambient air for 24 or 48 h for swab inoculation and at 30 or 35 degrees C in ambient air for 24 or 48 h for spot inoculation. The results for these methods were compared to the results for mecA gene detection by a PCR method. Given the ability to support growth and the results for susceptibility testing (the breakpoint for susceptible isolates was </=2 microg/ml), the best methods for CoNS isolates were (i) agar dilution by using MH medium supplemented with 4% NaCl and incubation at 35 degrees C for 48 h (no growth failures were noted, and sensitivity was 97.6%) and (ii) agar screen (swab inoculation) by using MH medium prepared in-house supplemented with 4% NaCl and containing 0.6 microg oxacillin/ml and incubation at 35 degrees C for 48 h (one isolate that did not carry the mecA gene did not grow, and the sensitivity was 100%). All but one (agar dilution without added NaCl and incubation at 30 degrees C for 48 h) of the methods tested revealed all oxacillin-resistant S. aureus isolates, and no growth failures occurred with any method. If the breakpoint for susceptibility was lowered to </=1 microg/ml for agar dilution methods, more CoNS isolates with oxacillin resistance related to the mecA gene were detected when 0 or 2% NaCl agar supplementation was used. Only one CoNS isolate with mecA gene-associated resistance was not detected by using agar dilution and MH medium supplemented with 4% NaCl with incubation for 48 h. When the breakpoint for susceptibility was decreased 10-fold (from 6.0 to 0.6 microg of oxacillin per ml) for the agar swab screen method, fully 100% of the CoNS isolates that carried the mecA gene were identified.
منابع مشابه
Prevalence of mecA Gene of Methicillin Resistant Staphylococcus spp. Isolated from Nosocomial Infections and Environmental Specimens in Sanandaj Hospitals, Kurdistan, Iran
Background: Methicillin resistant Staphylococcus aureus (MRSA) is one of the major agents for increasing number of serious hospital and community acquired infections. The aim of this study was to investigate the occurrence of the MRSA and mecA gene among nosocomial and environmental specimens in Kurdistan hospitals and determining the antibiotic resistance of the isolates. Materials and Method...
متن کاملDetection Of Methicillin Resistance In Staphylococcus Aureus By Disk Diffusion And PCR Methods
Background and Objective: Methicillin resistance in Staphylococcus aureus is an increasingly important clinical problem. A chromosomal gene, mecA, mediates resistance to penicillinase-resistant penicillins such as methicillin and oxacillin in Staphylococcus aureus. We evaluated the validity of disk diffusion test by using oxacillin, methicillin an...
متن کاملValidation of multiplex PCR strategy for simultaneous detection and identification of methicillin resistant Staphylococcus aureus.
Multiplex polymerase chain reaction (PCR) strategy is described for rapid identification of clinically relevant methicillin resistant Staphylococcus aureus (MRSA) that targets mecA and coagulase genes. In this study, 150 staphylococcal clinical isolates were used that included 40 isolates of MRSA, 55 isolates of methicillin susceptible S. aureus (MSSA), 44 isolates of methicillin susceptible co...
متن کاملIdentification of Methicillin Resistant Staphylococcus aureus (MRSA) and Methicillin Resistant Coagulase-Negative Staphylococcus (CoNS) in Clinical Settings
To evaluate different methods for the identification of methicillin-resistant Staphylococci and their reliability, 112 Staphylococcal isolates (32 Staphylococcus aureus isolates and 80 coagulase negative Staphylococci isolates “CoNS”) were collected from 118 nasal swab cultures and were subjected to three methods to detect oxacillin susceptibility of the isolates. The three methods were oxacill...
متن کاملCorrelation of Minimum Inhibitory Concentration Breakpoints and Methicillin Resistance Gene Carriage in Clinical Isolates of Staphylococcus epidermidis
Staphylococcus epidermidis is the most important member of coagulase negative staphylococci responsible for community and hospital acquired infections. Most clinical isolates of S. epidermidis are resistant to methicillin making these infections difficult to treat. In this study, correlation of methicillin resistance phenotype was compared with methicillin resistance (mecA) gene carriage in 55 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 9 شماره
صفحات -
تاریخ انتشار 1999