Left axillary pacemaker generator implantation with a direct puncture of the left axillary vein.

نویسندگان

  • Mahito Noro
  • Xin Zhu
  • Takahito Takagi
  • Naohiko Sahara
  • Yuriko Narabayashi
  • Hikari Hashimoto
  • Naoshi Ito
  • Yoshinari Enomoto
  • Keijirou Nakamura
  • Shingo Kujime
  • Tuyoshi Sakai
  • Takao Sakata
  • Kaoru Sugi
چکیده

BACKGROUND Pacemaker generators are routinely implanted in the anterior chest. However, where to place the generator may need to be considered from the mental, functional, and cosmetic standpoints. METHODS In this study, we performed the left axillary pacemaker generator implantation with a direct puncture of the left axillary vein in 40 consecutive patients, and evaluated the late safety and efficacy of this implantation. Complications, changes in the lead sensing, pacing threshold, and impedance were used as safety indexes for a mean follow-up of 3.4 years. In addition, the efficacy was also evaluated by comparing their questionnaire survey results to 119 patients in a control group of anterior chest implantation. RESULTS Lead dislodgements were observed in two patients of the experiment group. There were no migrations of generators from the implantation site or abnormal variations in the pacing threshold, lead sensing, or impedance. In the left anterior chest and left axillary groups, 85% and 10% of the patients were worried about an external impact, 80% and 25% were worried about electromagnetic interference, and 68% and 0% answered that the pacemaker implantation site was noticeable, respectively. Apparently, more patients had a sense of security and cosmetic satisfaction with the left axillary implantation. CONCLUSION The left axillary generator implantations may reduce the mental burden and cause no safety concerns, and may be performed if functional or cosmetic outcomes are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Venous spasm during pacemaker implantation.

A 75-years-old female presented with dyspnea and syncope. Electrocardiogram revealed atrial fibrillation and complete atrioventricular block. She was therefore listed for pacemaker implantation on the next day. Initial attempt at venous access was left axillary vein. A venogram showed good venous anatomy (Fig. 1a). Several attempts to puncture axillary vein were made. However, there was no good...

متن کامل

Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.

AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive pati...

متن کامل

A safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children

Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...

متن کامل

Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.

BACKGROUND Axillary vein puncture has been demonstrated to be an effective method for pacemaker and defibrillator leads implantation, without the complications encountered with the standard intrathoracic approach. OBJECTIVE Different techniques have been adopted for the cannulation of the axillary vein. We report our experience using the outer edge of the first rib below the inferior border o...

متن کامل

Percutaneous Transvenous Angioplasty of Left Innominate Vein Stenosis Following Right Side Permanent Pacemaker Implantation- A Left Femoral Vein to Left Axillary Vein Approach

Central venous stenosis after the insertion of a permanent pacemaker is a well recognized complication. This late complication is encountered when there is a need to change the pacemaker lead or extract it. We describe a young male who had such a complication after many years after right side pacemaker implantation. The lesion was managed percutaneously leading to placement of a new lead from t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2015