Respiratory Motion Analysis: Towards Gated Augmentation of the Liver
نویسندگان
چکیده
Laparoscopic surgery had a rapid development over the past decade. However, the view of the surgeon is limited to the image of the laparoscope. Augmented reality can provide further information to the surgeon by enabling a view inside the patient, and thus supporting a more precise and less invasive procedure. The limiting factors for realistic augmentation during liver surgery are movement and deformation of the organ due to respiratory motion. In our experiments we analyzed respiratory motion patterns of the liver caused by the respirator. Throughout our experiments we validated our assumption that repositioning after one breathing cycle is within a range of 1mm. For an optimal augmentation of the liver in the laparoscopic image we suggest to adjust the respirator thus that we have a static exhalation phase of two to three seconds on which our augmentation is performed.
منابع مشابه
Advanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...
متن کاملInvestigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy
Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...
متن کاملComparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging
AIM Respiratory motion affects cardiac PET-computed tomography (CT) imaging by reducing attenuation correction (AC) accuracy and by introducing blur. The aim of this study was to compare three approaches for reducing motion-induced AC errors and evaluate the inclusion of respiratory motion correction. MATERIALS AND METHODS AC with a helical CT was compared with averaged cine and gated cine CT...
متن کامل