Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.

نویسندگان

  • M L Yu
  • W L Chuang
  • C Y Dai
  • S C Chen
  • Z Y Lin
  • M Y Hsieh
  • L Y Wang
  • W Y Chang
چکیده

A second-generation hepatitis C virus (HCV) quantitative assay (COBAS AMPLICOR HCV MONITOR Test, version 2.0; COBAS HCM-2) has been developed, with the intention of achieving equivalent quantification of all HCV genotypes and improving assay performance. To evaluate the clinical performance of COBAS HCM-2 and its utility in predicting the response to alpha interferon treatment, sera from 215 chronic hepatitis C patients were analyzed and the results were compared with those obtained by the Quantiplex bDNA HCV RNA, version 2.0, assay (bDNA-2). The COBAS HCM-2 had significantly greater sensitivity than bDNA-2 (94.9 versus 88.4%; P < 0.001) when performed with sera from chronic hepatitis C patients who were viremic by a qualitative PCR test. The standard deviations for the within-run and between-run reproducibilities of COBAS HCM-2 were <0. 1 and <0.2, respectively, and it showed an improved linear range between genotypes with the threefold serial dilutions tested (r(2) = 0.986 to 0.995). The COBAS HCM-2 results were positively correlated with the bDNA-2 results, but the values for COBAS HCM-2 were on average 0.96 log lower than the values for bDNA-2. The mean difference in quantification values between these two assays did not differ among samples with different genotypes (0.70 to 1.00 log). No genotype-dependent difference in viral load was observed. The pretreatment viral load was significantly lower in complete responders. By using multivariate analysis, the viral load 2 weeks after the initiation of alpha interferon treatment was the strongest predictor of a complete response. In conclusion, COBAS HCM-2 demonstrated good sensitivity, linearity, and reproducibility and efficiency equal to that of bDNA-2 for the quantification of HCV genotypes 1 and 2. Hence, this assay provides a rapid and reliable method for the quantification of HCV RNA in serum and is useful for the planning of interferon treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of viral loads in patients with chronic hepatitis C with AMPLICOR HCV MONITOR version 1.0, COBAS HCV MONITOR version 2.0, and QUANTIPLEX HCV RNA version 2.0 assays.

The correlation between response to antiviral therapy and pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load. The aim of our study was to assess the clinical relevance of the newly developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, ...

متن کامل

Performance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.

A clinical evaluation of an automated quantitative PCR assay, the COBAS AMPLICOR HCV MONITOR test, version 2.0 (v2.0), was carried out to assess the performance of this test in comparison with that of the previous, manual version, the AMPLICOR HCV MONITOR test, and with that of nested PCR. Serial dilutions of serum samples infected with genotype 1b, 2a, or 3, as well as synthetic RNA transcript...

متن کامل

Evaluation of the invader assay for genotyping hepatitis C virus.

The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5' noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, ...

متن کامل

Evaluation of the COBAS TaqMan HCV test with automated sample processing using the MagNA pure LC instrument.

The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteris...

متن کامل

Comparison of qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and quantitative (COBAS AMPLICOR HCV monitor 2.0 versus VERSANT HCV RNA 3.0) assays for hepatitis C virus (HCV) RNA detection and quantification: impact on diagnosis and treatment of HCV infections.

Quantitative measurements of serum hepatitis C virus (HCV) RNA are becoming increasingly important in the management of HCV-infected patients. Here we compared two quantitative assays, the COBAS AMPLICOR HCV Monitor 2.0 assay (Roche Diagnostics) and the branched DNA-based VERSANT HCV RNA 3.0 assay (Bayer Diagnostics) for HCV RNA measurement in 344 samples derived from 120 patients with chronic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 8  شماره 

صفحات  -

تاریخ انتشار 2000