Perioperative changes of the intraocular pressure during the treatment of epiretinal membrane by using 25- or 27-gauge sutureless vitrectomy without gas tamponade
نویسندگان
چکیده
PURPOSE The purpose of this study was to compare perioperative intraocular pressures (IOPs) in 25- or 27-gauge microincision vitrectomy surgery (MIVS) and to evaluate the stability of postoperative sclerotomy closure. MATERIALS AND METHODS This is a retrospective review of 147 eyes treated for epiretinal membrane by using 25- or 27-gauge MIVS as the initial vitrectomy (25-gauge phacovitrectomy [25-P group]: 73 eyes, 25-gauge vitrectomy alone [25-A group]: 15 eyes, 27-gauge phacovitrectomy [27-P group]: 47 eyes, and 27-gauge vitrectomy alone [27-A group]: 12 eyes). Statistical analyses of perioperative IOPs on preoperative day (PreOp), postoperative day (POD)1, POD2, postoperative week 1, and postoperative month 1 were performed. RESULTS All self-sealing sclerotomies were obtained without gas tamponade at the end of surgery. Also, no significant differences were noted in the age and axial length among the 4 groups and in the surgical time between 25-P and 27-P groups and between 25-A and 27-A groups. Significant decreases in IOP were found at POD1 and POD2 in the 25-P, 25-A, and 27-P groups compared with PreOP, but not in the 27-A group. CONCLUSION Even though surgeons confirm that there is no leakage from sutureless sclerotomy and that a normal IOP is preserved at the end of 25- or 27-gauge MIVS, there is a possibility of postoperative sclerotomy leakage on the day of the surgery. Furthermore, postoperative sclerotomy self-sealing of the MIVS in previous intraocular lens implantation cases is considered to be acquired easily than that in phacovitrectomy.
منابع مشابه
Twenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery.
PURPOSE To compare visual outcomes, intraoperative and postoperative complications of 25-gauge transconjunctival sutureless vitrectomy (25-G TSV) versus conventional 20-gauge vitrectomy in epiretinal membrane (ERM) surgery. METHODS A retrospective comparative study was conducted on 200 eyes with idiopathic ERM who underwent either primary 20-gauge vitrectomy (n=95) or 25-G TSV (n=105) with 6 ...
متن کاملInvestigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions
BACKGROUND The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM g...
متن کاملBacterial endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy
PURPOSE To report a case of endophthalmitis following 25-gauge transconjunctival sutureless vitrectomy. DESIGN Observational case report. METHODS An 87-year-old male who underwent sutureless 25-gauge vitrectomy developed unilateral endophthalmitis. Vitreous culture revealed Staphylococcus coagulase-negative bacteria. He was subsequently treated with intravitreal antibiotics and oral prednis...
متن کاملInfluence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study
BACKGROUND Characteristic complications have been reported for transconjunctival sutureless vitrectomy, such as postoperative sclerotomy leakage and postoperative hypotony. Particular attention to sclerotomy closure is required in cases of silicone oil tamponade, because postoperative supplementation of silicone oil implies reoperation, whereas postoperative supplement of gas is comparatively e...
متن کاملUse of 25% sulfur hexafluoride gas mixture may minimize short-term postoperative hypotony in sutureless 25-gauge pars plana vitrectomy surgery
BACKGROUND The purpose of this study was to compare postoperative intraocular pressures and percentage of vitreous cavity gas fill one day following 25-gauge pars plana vitrectomy with 20% versus 25% sulfur hexafluoride (SF6) gas fill. METHODS This was a retrospective review of 187 consecutive cases of 25-gauge pars plana vitrectomy with complete fluid/gas exchange. The main outcome measures ...
متن کامل