A new sensitive automated assay for procalcitonin detection: LIAISON

نویسنده

  • Antonio Fortunato
چکیده

Objectives: To assess the performance of LIAISON s BRAHMS PCT s II GEN (DiaSorin, Saluggia, Italy) in procalcitonin (PCT) determination by comparing it to the assay reference method B R A H M S PCT KRYPTOR (Thermo Fisher Scientific Clinical Diagnostics, Hennigsdorf, Germany) and assessing its ability to discriminate between healthy subjects and patients with suspected infection. Methods: Diagnostic performance was evaluated on: a) 193 selected samples covering the assay range, whose procalcitonin levels were already evaluated with the B R A H M S PCT s KRYPTOR; b) prospective samples: 150 apparently healthy specimens obtained from a blood bank, 161 hospitalized patients (not with specific pathologies), 243 apparently healthy children. Results: The comparison of LIAISON s BRAHMS PCT s II GEN to the reference method B R A H M S PCT KRYPTOR yielded high correlation coefficients: slope of Deming fit equal to 1.04 (95% CI: 0.99–1.09) with an intercept equal to 0.05 (95% CI: 0.09 to 0.19) and a high concordance (98.4% (95% CI: 95.5–99.7%)) at the 0.5 ng/mL cut-off. Moreover, the results obtained using prospective samples showed: (i) no samples with PCT concentration 40.5 ng/mL (cut-off) for the apparently healthy adults (highest value1⁄40.033 ng/mL, 95th percentile and 97.5th percentile o0.02 ng/mL); (ii) 2 samples 40.5 ng/mL for hospitalized patients (highest value1⁄40.715 ng/mL, 95th percentile: 0.054 ng/mL; 97.5th percentile: 0.088 ng/mL); (iii) 3 samples 40.5 ng/mL for the healthy children population (highest value1⁄40.713 ng/mL, 95th percentile: 0.155 ng/mL; 97.5th percentile: 0.275 ng/mL). Conclusion: The fully automated LIAISON s BRAHMS PCT s II GEN agrees well with the reference method and is suitable for early diagnosis of sepsis, severe bacterial infection and guiding antibiotic therapy. & 2016 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new sensitive automated assay for procalcitonin detection: LIAISON® BRAHMS PCT® II GEN

OBJECTIVES To assess the performance of LIAISON® BRAHMS PCT® II GEN (DiaSorin, Saluggia, Italy) in procalcitonin (PCT) determination by comparing it to the assay reference method B·R·A·H·M·S PCT KRYPTOR (Thermo Fisher Scientific Clinical Diagnostics, Hennigsdorf, Germany) and assessing its ability to discriminate between healthy subjects and patients with suspected infection. METHODS Diagnost...

متن کامل

Significance of Serum Procalcitonin Level in the Early Diagnosis of Neonatal Sepsis

Background: Sepsis in neonates presents itself with non-specific clinical features which makes early diagnosis difficult. However, procalcitonin (PCT) and other inflammatory markers have recently been considered as sensitive markers for the early detection of neonatal sepsis. Therefore, the present study aimed to determine the diagnostic value of PCT in the early detection of neonatal sepsis an...

متن کامل

Analyzed for Procalcitonin (liaison

Brahms PCT), yielding a result of 0.88 g/L, slightly higher than the cutoff value (0.58 g/L). The crossreactivity with procalcitonin might be more likely in our sample measured with a polyclonal assay. Other interferences cannot be excluded. The 2 CT assays give markedly different results. The introduction of an internationally agreed upon standard would contribute to optimizing the CT assay, t...

متن کامل

Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

BACKGROUND The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. METHODS We studied 228 osteoporo...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...