Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla.
نویسندگان
چکیده
OBJECTIVES To evaluate the potential use of a novel 3D turbo spin-echo (TSE) T2-weighted (T2w) technique for assessing the vessel wall in the superficial femoral artery at 3.0 T. BACKGROUND Magnetic resonance imaging can be used for the noninvasive assessment of atherosclerotic plaque burden in the peripheral circulation. Although black-blood 2D TSE techniques have been used for femoral arterial wall imaging, these techniques require prolonged imaging time to cover a large field of view required to cover the leg. Recently, variable-flip-angle 3D TSE T2w (SPACE) has been introduced as a fast vessel wall imaging technique with submillimeter spatial resolution. A systematic investigation of the application of this technique to femoral arterial wall imaging has yet to be performed. METHODS Fifteen healthy volunteers and 3 patients with peripheral arterial disease (PAD) underwent 3D SPACE imaging of the superficial femoral artery at 3.0 T, with the conventional 2D TSE T2w imaging as a reference. Muscle-lumen contrast to noise ratio (CNR) and wall/lumen volumes (WV, LV) were measured at the matched locations on the 3D and 2D image sets. Statistical comparison on a per-subject basis was conducted to determine the difference and agreement between 3D SPACE and the 2D TSE techniques. RESULTS The 3D SPACE data sets enabled vessel visualization from arbitrary orientation through multiplanar reformation technique. Muscle-lumen CNR was significantly higher with 3D SPACE than with the 2D TSE (3.12 +/- 0.84 vs. 2.17 +/- 0.34, P < 0.01). This trend was confirmed when CNR efficiency (CNR(eff)) values were further compared. A similar trend was observed in PAD patients (SPACE vs. 2D TSE T2w: CNR 2.35 +/- 0.13 vs. 1.77 +/- 0.25; CNR(eff) 15.35 +/- 0.61 vs. 3.59 +/- 2.62. all P < 0.05). Measurements of WV and LV from the 3D and 2D techniques were highly correlated in volunteers and PAD patients (volunteers, WV: linear regression r2 = 0.98, LV: r2 = 0.98, P < 0.001 for both; patients, WV: linear regression r2 = 0.96, LV: r2 = 0.94, P < 0.001 for both). CONCLUSION We established the feasibility of using the 3D SPACE technique for vessel wall imaging in the superficial femoral artery at 3.0T. High, isotropic-resolution SPACE images, with the aid of multiplanar reformation, enable superior vessel wall visualization. Superior blood signal suppression comparable to vessel wall morphologic measurements, and superior time efficiency compared to conventional 2D TSE imaging indicate the great potential of the SPACE method as a noninvasive imaging technique for the assessment of atherosclerotic plaque burden in PAD patients.
منابع مشابه
Intracranial arterial wall imaging using high-resolution 3-tesla contrast-enhanced MRI.
BACKGROUND Conventional arterial imaging focuses on the vessel lumen but lacks specificity because different pathologies produce similar luminal defects. Wall imaging can characterize extracranial arterial pathology, but imaging intracranial walls has been limited by resolution and signal constraints. Higher-field scanners may improve visualization of these smaller vessels. METHODS Three-tesl...
متن کاملGadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla
Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years)...
متن کامل1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study
OBJECTIVES The aim of this study was to investigate and compare the feasibility as well as potential impact of altered magnetic field properties on image quality and potential artifacts of 1.5 Tesla, 3 Tesla and 7 Tesla non-enhanced abdominal MRI. MATERIALS AND METHODS Magnetic Resonance (MR) imaging of the upper abdomen was performed in 10 healthy volunteers on a 1.5 Tesla, a 3 Tesla and a 7...
متن کاملQuantitative evaluation of ischemic myocardial scar tissue by unenhanced T1 mapping using 3.0 Tesla MR scanner.
PURPOSE We aimed to use a noninvasive method for quantifying T1 values of chronic myocardial infarction scar by cardiac magnetic resonance imaging (MRI), and determine its diagnostic performance. MATERIALS AND METHODS We performed cardiac MRI on 29 consecutive patients with known coronary artery disease (CAD) on 3.0 Tesla MRI scanner. An unenhanced T1 mapping technique was used to calculate T...
متن کاملIsotropic 3D T2-weighted MR imaging for female pelvis with 3 Tesla MRI: Feasibility study
Objective: The aim of this study was to compare the quality of images obtained with 3D T2-weighted sequence with the quality of conventional 2D T2-weighted images. Subjects and Methods: Thirty consecutively registered patients (average age, 55 year; age range 32-79 years) underwent imaging at 3.0 T with a 6-element body array coil. All imaging was performed with three T2-weighted images: 3D axi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 44 9 شماره
صفحات -
تاریخ انتشار 2009