Accuracy performance of the Medtronic NexSensor™ for 6 days in an inpatient setting using abdomen and buttocks insertion sites.

نویسندگان

  • Tim Peoples
  • Timothy Bailey
  • Brazg Ronald
  • Howard C Zisser
  • Bob Janowski
  • Suiying Huang
  • Cary Talbot
  • Qingqing Yang
چکیده

BACKGROUND Users of continuous glucose monitoring are concerned with product accuracy and choice of insertion site. The Medtronic NexSensor™ was evaluated for accuracy during 6 days of wear when inserted in the abdomen and buttocks areas. METHODS Adults (ages 18-75) with type 1 diabetes wore two sensors simultaneously for 6 days, one each inserted in the abdomen and buttocks. Subjects underwent a frequent blood sampling study for 12 hours, during which time reference blood glucose values were obtained every 15 minutes and compared to sensor values. RESULTS Sixty-three subjects were enrolled, and 61 subjects completed the study. The mean agreement rate between sensor and blood glucose values was 75.5% [95% confidence interval (CI), 69.5, 81.4] at the abdomen site, 73.8% (95% CI, 68.8, 78.8) at the buttocks site, and 75.6% (95% CI, 70.8, 80.4) when sensor and reference data were combined between sites. Over 90% of paired sensor-reference values on Clarke error grids were within the A and B ranges. The mean absolute relative differences were 17.1% at the abdomen site, 16.5% at the buttocks site, and 16.8% when sites were combined. CONCLUSION The NexSensor was accurate for inpatient, frequent-sample testing for 6 days when inserted into the abdomen and buttocks. The results of this study also provide evidence that both the abdomen and buttocks are suitable as sensor insertion sites.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Day and Night Closed-Loop Control Using the Integrated Medtronic Hybrid Closed-Loop System in Type 1 Diabetes at Diabetes Camp.

OBJECTIVE To evaluate the feasibility and efficacy of a fully integrated hybrid closed-loop (HCL) system (Medtronic MiniMed Inc., Northridge, CA), in day and night closed-loop control in subjects with type 1 diabetes, both in an inpatient setting and during 6 days at diabetes camp. RESEARCH DESIGN AND METHODS The Medtronic MiniMed HCL system consists of a fourth generation (4S) glucose sensor...

متن کامل

Comparison of Parametric and Non-parametric EEG Feature Extraction Methods in Detection of Pediatric Migraine without Aura

Background: Migraine headache without aura is the most common type of migraine especially among pediatric patients. It has always been a great challenge of migraine diagnosis using quantitative electroencephalography measurements through feature classification. It has been proven that different feature extraction and classification methods vary in terms of performance regarding detection and di...

متن کامل

Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.

OBJECTIVE This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose va...

متن کامل

ارزیابی کارایی نسبی بیمارستان‌های دولتی استان یزد با استفاده از مدل تحلیل پوششی داده‌ها

Introduction: Performance measurement, programming and goal setting for performance improvement are needed for organizations to improve their performance. Despite advancement in performance measurement systems, many organizations still emphasize on old models. Methods: This paper analyzes the efficiency of Yazd governmental hospitals by using DEA model from 2004 to 2006. The inputs in DEA...

متن کامل

بررسی مقایسه ای کیفیت زندگی بیماران مبتلا به مولتیپل میلوما بعد از پیوند مغز استخوان سرپایی و بستری

Introduction: Bone marrow transplantation is one of the treatment modalities in many hematologic disorders. In recent years, bone marrow transplantation is increasingly being delivered in the outpatient setting. Some studies suggest that outpatient transplantation has many advantages. The aim of this study was to compare the quality of life in outpatient and inpatient multiple myeloma patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2011