Memory Efficient LDDMM for Lung CT
نویسندگان
چکیده
In this paper a novel Large Deformation Diffeomorphic Metric Mapping (LDDMM) scheme is presented which has significantly lower computational and memory demands than standard LDDMM but achieves the same accuracy. We exploit the smoothness of velocities and transformations by using a coarser discretization compared to the image resolution. This reduces required memory and accelerates numerical optimization as well as solution of transport equations. Accuracy is essentially unchanged as the mismatch of transformed moving and fixed image is incorporated into the model at high resolution. Reductions in memory consumption and runtime are demonstrated for registration of lung CT images. State-of-the-art accuracy is shown for the challenging DIR-Lab chronic obstructive pulmonary disease (COPD) lung CT data sets obtaining a mean landmark distance after registration of 1.03 mm and the best average results so far.
منابع مشابه
Detection of Time-Varying Structures by Large Deformation Diffeomorphic Metric Mapping to Aid Reading of High-Resolution CT Images of the Lung
OBJECTIVES To evaluate the accuracy of advanced non-linear registration of serial lung Computed Tomography (CT) images using Large Deformation Diffeomorphic Metric Mapping (LDDMM). METHODS FIFTEEN CASES OF LUNG CANCER WITH SERIAL LUNG CT IMAGES (INTERVAL: 62.2±26.9 days) were used. After affine transformation, three dimensional, non-linear volume registration was conducted using LDDMM with or...
متن کاملA Multi-scale Kernel Bundle for LDDMM: Towards Sparse Deformation Description across Space and Scales
The Large Deformation Diffeomorphic Metric Mapping framework constitutes a widely used and mathematically well-founded setup for registration in medical imaging. At its heart lies the notion of the regularization kernel, and the choice of kernel greatly affects the results of registrations. This paper presents an extension of the LDDMM framework allowing multiple kernels at multiple scales to b...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملPatient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body
This paper describes an automated procedure for creating detailed patient-specific pediatric dosimetry phantoms from a small set of segmented organs in a child's CT scan. The algorithm involves full body mappings from adult template to pediatric images using multichannel large deformation diffeomorphic metric mapping (MC-LDDMM). The parallel implementation and performance of MC-LDDMM for this a...
متن کاملStereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters
Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...
متن کامل