Comparison of disposable sutureless silicone ring and traditional metal ring in 23-gauge vitrectomy combined with cataract surgery

نویسندگان

  • Jian-Guo Wu
  • Rui-Hua Wei
  • Ai-Hua Liu
  • Xiao-Xu Zhou
  • Guo-Ling Sun
  • Xiao-Rong Li
چکیده

BACKGROUND The purpose of this prospective, interventional, comparative case series was to evaluate the efficiency and feasibility of a disposable sutureless silicone lens ring for corneal contact lens stabilization during combined 23-gauge vitrectomy and cataract surgery. METHODS We developed a ring consisting of a single silicone component with three footplates along the ring margin to fit cannulae for holding conventional contact lenses. Thirty eyes from 30 patients with cataract and vitreoretinal disease were included, and divided into two matched groups according to disease type and ring used. In Group A, we used a 23-gauge transconjunctival vitrectomy system and a disposable sutureless silicone lens ring (n = 15). In Group B, we used a 23-gauge transconjunctival vitrectomy system and a conventional metal lens ring (n = 15). The main outcome measures were: time required for vitrectomy preparation, rate of intraoperative corneal limbus bleeding, and limbus scar rate at the final follow-up visit. RESULTS Thirty cases were successfully completed. The average vitrectomy preparation time was less in Group A than in Group B (P < 0.01), and the average preparation time saved was 3.94 minutes. None of the Group A patients had intraoperative bleeding or postoperative scarring, whereas all 15 Group B cases had bleeding and five had scarring. There was a statistically significant difference between Group A and Group B for these complications (P ≤ 0.05). CONCLUSION This report demonstrates the advantages of using a sutureless silicone ring during combined 23-gauge vitrectomy and cataract surgery. Using this method could allow extra time for the surgeon to pay more attention to complex vitreoretinal procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case of Sympathetic Ophthalmia after 23-Gauge Transconjunctival Sutureless Vitrectomy

PURPOSE We report a case of a sympathetic ophthalmia that occurred after 23-gauge transconjunctival sutureless vitrectomy for a retinal detachment. CASE REPORT A 41-year-old Japanese woman underwent combined phacoemulsification with intraocular lens implantation and 23-gauge transconjunctival sutureless vitrectomy for a rhegmatogenous retinal detachment in the right eye. Endolaser photocoagul...

متن کامل

Combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification for rhegmatogenous retinal detachment repair.

AIM To assess the outcomes of combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for rhegmatogenous retinal detachment (RRD) repair. METHODS This was a retrospective, consecutive, non-comparative, interventional case series of 30 eyes of 30 patients who underwent combined sutureless vitrectomy and clear corneal cataract surgery for...

متن کامل

Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula...

متن کامل

Active Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?

OBJECTIVES To evaluate the safety and efficacy of active silicone oil removal with a 23-gauge (G) transconjunctival sutureless system. MATERIALS AND METHODS One hundred sixteen eyes of 113 patients who had previous retinal detachment surgery with pars plana vitrectomy and silicone oil injection surgery, and underwent silicone oil removal surgery with 23-G transconjonctival sutureless techniqu...

متن کامل

23-gauge vitrectomy and silicone oil tamponade with and without phacoemulsification in rhegmatogenous retinal detachment.

The aim of this study is to assess clinical outcomes of 23-gauge vitrectomy and silicone oil (SO) tamponade combined with and without phacoemulsification (PE) in rhegmatogenous retinal detachment (RRD). The study included forty eyes of 40 patients that underwent 23-gauge vitrectomy and SO tamponade combined with and without PE. Twenty eyes of 20 cases, of whom underwent 23-gauge vitrectomy and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011