A novel radiation protection device based on tungsten functional paper for application in interventional radiology
نویسندگان
چکیده
Tungsten functional paper (TFP), which contains 80% tungsten by weight, has radiation-shielding properties. We investigated the use of TFP for the protection of operators during interventional or therapeutic angiography. The air kerma rate of scattered radiation from a simulated patient was measured, with and without TFP, using a water-equivalent phantom and fixed C-arm fluoroscopy. Measurements were taken at the level of the operator's eye, chest, waist, and knee, with a variable number of TFP sheets used for shielding. A Monte Carlo simulation was also utilized to analyze the dose rate delivered with and without the TFP shielding. In cine mode, when the number of TFP sheets was varied through 1, 2, 3, 5, and 10, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.9%, 29.9%, 41.6%, 50.4%, and 56.2%; at chest level, 25.3%, 33.1%, 34.9%, 46.1%, and 44.3%; at waist level, 45.1%, 57.0%, 64.4%, 70.7%, and 75.2%; and at knee level, 2.1%, 2.2%, 2.1%, 2.1%, and 2.1%. In fluoroscopy mode, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.8%, 30.3%, 34.8%, 51.1%, and 58.5%; at chest level, 25.8%, 33.4%, 35.5%, 45.2%, and 44.4%; at waist level, 44.6%, 56.8%, 64.7%, 71.7%, and 77.2%; and at knee level, 2.2%, 0.0%, 2.2%, 2.8%, and 2.5%. The TFP paper exhibited good radiation-shielding properties against the scattered radiation encountered in clinical settings, and was shown to have potential application in decreasing the radiation exposure to the operator during interventional radiology.
منابع مشابه
A Novel Design for Production of Efficient Flexible Lead-Free Shields against X-ray Photons in Diagnostic Energy Range
Background: Lead-based radiation shields are widely used in radiology departments to protect both workers and patients from any unnecessary exposure to ionizing radiation. Recently there has been a great deal of concern expressed about the toxicity of lead. Human lead toxicity is well documented. In that light, production of environmentally-friendly lead-free radiation shields with less weight ...
متن کاملApplication of personal non-lead nano-composite shields for radiation protection in diagnostic radiology: a systematic review and meta-analysis
composites with micro- and nano-metal fillers has attracted the attention of researchers for radiation shielding applications. Lead toxicity and heaviness have oriented extensive research toward the use of non-lead composite shields. The present study aimed to systematically review the efficiency of the composite shields of various micro- and nano-sized materials as composite shields have been ...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کاملAbsorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models
Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...
متن کاملCT fluoroscopy shielding: decreases in scattered radiation for the patient and operator.
PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surfac...
متن کامل