A faster radioimmunoassay of progesterone in plasma, with use of polyethylene glycol as precipitant.
نویسندگان
چکیده
We report a reliable radioimmunoassay for plasma progesterone in which polyethylene glycol ("Carbowax 6000") is used to separate antibody-bound and free hormone. Initially, progesterone is concentrated by putting the sample through a column of LH-20 Sephadex. Procedural losses in each sample are not monitored. We compared the reliability and practicality of this method with that of another method in which procedural losses are monitored for each sample; accuracy and precision were similar. Our method saves technical assay time and scintillation counter space and time without sacrificing reliability.
منابع مشابه
Nonchromatographic radioimmunoassay of unconjugated estriol in plasma, with polyethylene glycol as precipitant.
We describe a rapid, reliable radioimmunoassay for unconjugated estriol in plasma. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay is sensitive (25 pg for standards), precise, and accurate. At high and low concentrations of estriol, intra-assay coefficients of variation were 7.1% and 7.6%, respectively, and inter-assay coefficients of variation...
متن کاملEnzyme immunoassay of estrogen-like substances in plasma, with polyethylene glycol as precipitant.
We devised an enzyme immunoassay for plasma estrogen-like substances in pregnancy, using estriol covalently linked to horseradish peroxidase. Free and bound steroid were separated by use of polyethylene glycol reagent. The assay satisfies the normal criteria of specificity and precision. Results obtained by radioimmunoassay and enzyme immunoassay agreed well. Our assay is particularly applicabl...
متن کاملHuman plasma derived drugs separation by fractionation of plasma with polyethylene glycol
Background: There are varieties of purification techniques for separation of human plasma proteins such as salting out, ion exchange chromatography, and ethanol fractionation. There are limitations for each method, for example in salting out method, the salt has to be removed in an additional step. Ion exchange chromatography is difficult for scaling up, and plasma fractionation is a time consu...
متن کاملNonspecific binding as a source of error in thyrotropin radioimmunoassay with polyethylene glycol as separating agent.
We investigated the effects of nonspecific binding on thyrotropin values obtained by radioimmunoassay in which polyethylene glycol is used as precipitant. Differences in nonspecific binding among individual samples were significant (F-test, p less than 0.001, range 5.5 to 14.1%). Non-specific binding and total serum protein were directly correlated (r = 0.472, n = 59; p less than 0.001). Nonspe...
متن کاملRadioimmunoassay of plasma testosterone, with use of polyethylene glycol to separate antibody-bound and free hormone.
We have developed a reliable radioimmunoassay for testosterone in plasma, polyethylene glycol ("Carbowax 6000") being used to separate antibody-bound and free hormone. Testosteron is separated from interfering steroids, notably dihydrotestosterone, by liquid-liquid partition chromatography on infusorial earth (Celite). The assay is sensitive (9 pg for standards), precise, and accurate. The lowe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 22 10 شماره
صفحات -
تاریخ انتشار 1976