Optimization of diffusion spectrum imaging and q-ball imaging on clinical MRI system

نویسندگان

  • Li-Wei Kuo
  • Jyh-Horng Chen
  • Van J. Wedeen
  • Wen-Yih Isaac Tseng
چکیده

Mapping complex crossing fibers using diffusion MRI techniques requires adequate angular precision and accuracy. Beyond diffusion tensor imaging (DTI), high angular resolution sampling schemes such as diffusion spectrum imaging (DSI) and q-ball imaging (QBI) were proposed to resolve crossing fibers. These schemes require hundreds of data approximately five to ten times more than DTI, offsetting their clinical feasibility. To facilitate its clinical application, optimum values of highest diffusion sensitivity (bmax) must be investigated under the constraint of scan time and gradient performance. In this study, simulation of human data sets and a following verification experiment were performed to investigate the optimum bmax of DSI and QBI. Four sampling schemes, two with high sampling number, i.e., DSI515 and QBI493, and two with low sampling number, i.e., DSI203 and QBI253, were compared. Deviation angle and angular dispersion were used to evaluate the precision and accuracy among different bmax of each scheme. The results indicated that the optimum bmax was a trade-off between SNR and angular resolution. At their own optimum bmax, the reduced sampling schemes yielded angular precision and accuracy comparable to the high sampling schemes. On our current 3 T system, the optimum bmax (s/mm2) were 6500 for DSI515, 4000 for DSI203, 3000 for QBI493 and 2500 for QBI253. DSI was incrementally more accurate than QBI, but required a greater demand for gradient performance. In conclusion, our systematic study of optimum bmax in different sampling schemes and the consideration derived wherein could be helpful to determine optimum sampling schemes in other MRI systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PDFlib PLOP: PDF Linearization, Optimization, Protection

This chapter reviews multiple-fiber reconstruction algorithms for diffusion magnetic resonance imaging (MRI) and provides some initial comparative results for two such algorithms, q-ball imaging and PASMRI, on data from a typical clinical diffusion MRI acquisition. The chapter highlights the problems with standard approaches, such as diffusion-tensor MRI, to motivate a recent set of alternative...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Evaluation of the relationship between axon injury and clinical symptoms in patients with multiple sclerosis using diffusion tensor MRI imaging

Background: Magnetic resonance imaging (MRI) is a non-invasive imaging technology that shows detailed anatomical and pathological images. It is often used for disease detection, diagnosis, and treatment monitoring, in particular with neurodegenerative diseases, such as Multiple sclerosis (MS), Alzheimer's and amyotrophic lateral sclerosis. However, conventional MRI provides only qualitative inf...

متن کامل

Impact of outliers on diffusion tensor and Q-ball imaging: clinical implications and correction strategies.

PURPOSE To measure the impact of corrupted images often found to occur in diffusion-weighted magnetic resonance imaging (DW-MRI). To propose a robust method for the correction of outliers, applicable to diffusion tensor imaging (DTI) and q-ball imaging (QBI). MATERIALS AND METHODS Monte Carlo simulations were carried out to measure the impact of outliers on DTI and QBI reconstruction in a sin...

متن کامل

A Connectome-Based Comparison of Diffusion MRI Schemes

Diffusion MRI has evolved towards an important clinical diagnostic and research tool. Though clinical routine is using mainly diffusion weighted and tensor imaging approaches, Q-ball imaging and diffusion spectrum imaging techniques have become more widely available. They are frequently used in research-oriented investigations in particular those aiming at measuring brain network connectivity. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 41 1  شماره 

صفحات  -

تاریخ انتشار 2008