Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.
نویسندگان
چکیده
BACKGROUND Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. METHODS AND RESULTS Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) <5 kg and 2 of 13 (15%) >5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. CONCLUSIONS Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg.
منابع مشابه
Outcomes of long-term endocavitary cardiac pacing in children
Background: The development of neonatal cardiology and cardiac surgery, as well as the earlier diagnosis of congenital defects, arrhythmias, and cardiac conduction disorders, contributed to the systematic increase of the number of children and young adults undergoing electrophysiological procedures, as well as to the reduction of the age at which these procedures are performed. Children requiri...
متن کاملA safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children
Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...
متن کاملffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site
Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...
متن کاملPermanent ventricular pacemakers. Comparison of transthoracic and transvenous implantation.
In the series of 86 patients with the Stokes-Adams syndrome or with symptomatic bradycardia managed with permanently implanted ventricular pacemakers reported on, 35 patients had primary implantation of epicardial leads at thoracotomy and 51 had transvenous endocardial electrodes passed via the jugular venous system for permanent ventricular pacing. The transvenous method of permanent pacemaker...
متن کاملUse of cardiac pacing after the Mustard operation for transposition of the great arteries.
The most frequent complication of the venous redirection (Mustard or Senning) operation for transposition of the great arteries is cardiac arrhythmia. Drug treatment of tachyarrhythmia often worsens bradyarrhythmia. Pacemakers can now treat both arrhythmias. The technique for implantation of pacemakers after redirection for transposition has changed over time from thoracotomy to subxiphoid to t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2016